Ventricular oversensing in 518 patients with implanted cardiac defibrillators: incidence, complications, and solutions.

T Rauwolf1, M Guenther, N Hass, A Schnabel, M Bock, M U Braun, R H Strasser.   

Abstract

The present study evaluates the incidence of various complications in implanted cardiac defibrillators (ICD) therapy due to ventricular oversensing (VO) and its complications. From June 1998 to May 2005, we retrospectively screened 518 patients (1085.6 patient years) for the occurrence of VO episodes (441 male, 77 female). The overall incidence was 7.3% (n = 38) with inappropriate shock deliveries accounting for 2.3% (n = 12). All VO episodes were caused by either T-wave oversensing (n = 10), myopotentials (n = 8), electrode failure (n = 5), interference with electromagnetic fields (n = 3), double-counting (n = 4), pacemaker interactions (n = 2), or others (n = 2). There were five life-threatening events due to inappropriate ICD reaction. In eight (22%) cases, ICD reprogramming was able to avoid further oversensing episodes (e.g. adaptation of sensitivity, T-wave suppression feature), 13 (35%) patients had to undergo invasive procedures (e.g. electrode replacing) to suppress VO, 16 (43%) were told to avoid the trigger situation, and one demanded to deactivate all ICD therapies because of inappropriate shock delivery. Our data demonstrate that VO is a rare complication, but might lead to life-threatening events. In most cases, VO episodes could be prevented by appropriate ICD reprogramming or avoidance of the initiating trigger.

Entities:  

Mesh:

Year:  2007        PMID: 17897927     DOI: 10.1093/europace/eum195

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  9 in total

1.  [Single- and dual-chamber ICDs: Are there still significant differences compared to pacemakers with regard to implantation and follow-up?].

Authors:  M Stockburger
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-12

2.  Stimulation of the brachial plexus by a dislocated ICD lead: a rare complication.

Authors:  J Elders; M Chagri; J S Bos; J L R M Smeets
Journal:  Neth Heart J       Date:  2009-06       Impact factor: 2.380

Review 3.  Troubleshooting implantable cardioverter-defibrillators: an overview for physicians who are not electrophysiologists.

Authors:  Mohammad Saeed
Journal:  Tex Heart Inst J       Date:  2011

4.  Long-term incidence of inappropriate shocks in patients with implantable cardioverter defibrillators in clinical practice-an underestimated complication?

Authors:  Daniel Hofer; Jan Steffel; David Hürlimann; Laurent Haegeli; Thomas F Lüscher; Firat Duru; Urs Eriksson; Nazmi Krasniqi
Journal:  J Interv Card Electrophysiol       Date:  2017-11-25       Impact factor: 1.900

5.  Surface electromyography of myopotential oversensing provoked by simultaneous straining and leftward twisting in a patient with an implantable cardioverter defibrillator.

Authors:  Yoichi Ajiro; Tsuyoshi Shiga; Morio Shoda; Nobuhisa Hagiwara
Journal:  Heart Vessels       Date:  2016-08-30       Impact factor: 2.037

6.  Electromagnetic interference in implantable cardioverter defibrillators: present but rare.

Authors:  Gesa von Olshausen; Ina-Christine Rondak; Carsten Lennerz; Verena Semmler; Christian Grebmer; Tilko Reents; Sonia Ammar-Busch; Alessandra Buiatti; Felix Bourier; Isabel Deisenhofer; Christof Kolb
Journal:  Clin Res Cardiol       Date:  2016-01-29       Impact factor: 5.460

7.  Myopotential oversensing notified by Lead Integrity Alert in a patient with implantable cardioverter defibrillator with a dedicated bipolar epicardial sensing lead.

Authors:  Kyoichiro Yazaki; Yoichi Ajiro; Shun Hasegawa; Masahiro Watanabe; Kei Tsukamoto; Keiko Mizobuchi; Takashi Saito; Fumiaki Mori; Kazunori Iwade
Journal:  Clin Case Rep       Date:  2016-10-11

8.  Intermittent failure of pacing output caused by algorithm to prevent T-wave oversensing.

Authors:  Imre Hunyor; Hany S Abed; Raymond W Sy; Emily C Hodkinson; Peter Santucci; Mark A McGuire
Journal:  HeartRhythm Case Rep       Date:  2016-03-31

9.  An inappropriate defibrillator shock during ventricular tachycardia.

Authors:  Mariana Faustino; Francisco Madeira; Carlos Morais
Journal:  Indian Pacing Electrophysiol J       Date:  2015-10-19
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.