Comprehensive three-dimensional gas chromatography with parallel factor analysis.

Nathanial E Watson1, W Christopher Siegler, Jamin C Hoggard, Robert E Synovec.   

Abstract

Development of a comprehensive, three-dimensional gas chromatograph (GC3) instrument is described. The instrument utilizes two six-port diaphragm valves as the interfaces between three, in-series capillary columns housed in a standard Agilent 6890 gas chromatograph fitted with a high data acquisition rate flame ionization detector. The modulation periods for sampling column one by column two and column two by column three are set so that a minimum of three slices (more commonly four or five) are acquired by the subsequent dimension resulting in both comprehensive and quantitative data. A 26-component test mixture and quantitative standards are analyzed using the GC3 instrument. A useful methodology for three-dimensional (3D) data analysis is evaluated, based on the chemometric technique parallel factor analysis (PARAFAC). Since the GC3 instrument produces trilinear data, we are able to use this powerful chemometric technique, which is better known for the analysis of two-dimensional (2D) separations with multichannel detection (e.g., GC x GC-TOFMS) or multiple samples (or replicates) of 2D data. Using PARAFAC, we mathematically separate (deconvolute) the 3D data "volume" for overlapped analytes (i.e., ellipsoids), provided there is sufficient chromatographic resolution in each of the three separation dimensions. Additionally, PARAFAC is applied to quantify analyte standards. For the quantitative analysis, it is demonstrated that PARAFAC may provide a 10-fold improvement in the signal-to-noise ratio relative to a traditional integration method applied to the raw, baseline-corrected data. The GC3 instrument obtains a 3D peak capacity of 3500 at a chromatographic resolution of one in each separation dimension. Furthermore, PARAFAC deconvolution provides a considerable enhancement in the effective 3D peak capacity.

Year:  2007        PMID: 17896828     DOI: 10.1021/ac070829x

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  The impact of sampling time on peak capacity and analysis speed in on-line comprehensive two-dimensional liquid chromatography.

Authors:  Lawrence W Potts; Dwight R Stoll; Xiaoping Li; Peter W Carr
Journal:  J Chromatogr A       Date:  2010-07-15       Impact factor: 4.759

Review 2.  Perspectives on recent advances in the speed of high-performance liquid chromatography.

Authors:  Peter W Carr; Dwight R Stoll; Xiaoli Wang
Journal:  Anal Chem       Date:  2011-02-22       Impact factor: 6.986

Review 3.  Latest Trends on the Future of Three-Dimensional Separations in Chromatography.

Authors:  Noor Abdulhussain; Suhas Nawada; Peter Schoenmakers
Journal:  Chem Rev       Date:  2021-04-20       Impact factor: 60.622

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.