Literature DB >> 17896411

Clinical outcomes of dexamethasone-eluting stent implantation in ST-elevation acute myocardial infarction.

Santiago Jimenez-Valero1, Belen Santos, Fernando Pajin, Tomas Canton, Esther Lazaro, Jose Moreu, Gonzalo Hernandez, Luis Rodriguez Padial.   

Abstract

OBJECTIVES: The aim of our study was to evaluate the safety and midterm clinical results of dexamethasone-eluting stent (DexES) implantation in ST-segment elevation acute myocardial infarction (STEMI).
BACKGROUND: Inflammation plays a pivotal role in both inestabilization of coronary atherosclerotic plaques and development of restenosis after stent placement. Antiinflammatory agents may attenuate those mechanisms and improve clinical outcomes. There is little information about clinical results of DexES and no data are available about their utilization during percutaneous coronary intervention (PCI) in STEMI.
METHODS: Consecutive patients with STEMI that underwent primary or rescue PCI in our institution were treated with DexES. Clinical follow-up with routine realization of noninvasive test for detection of myocardial ischemia and coronariography if necessary, were performed. The objective of the study was to evaluate the rate of MACE (death, reinfarction, or target lesion revascularization) during midterm follow-up.
RESULTS: The procedure was successful in 96.7% of cases. There were no in-hospital deaths or reinfarctions. One acute stent thrombosis occurred and no subacute thrombosis were observed. During a mean follow-up period of 384 days, cardiac-related death was 1.1%, there were no reinfarctions or late stent thrombosis and target lesion revascularization rate was 4.2%.
CONCLUSION: We conclude that utilization of DexES for PCI in STEMI is safe and provides good midterm clinical outcomes. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17896411     DOI: 10.1002/ccd.21131

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Size effect of PLGA spheres on drug loading efficiency and release profiles.

Authors:  G J S Dawes; L E Fratila-Apachitei; K Mulia; I Apachitei; G-J Witkamp; J Duszczyk
Journal:  J Mater Sci Mater Med       Date:  2009-01-22       Impact factor: 3.896

2.  In vivo evaluation of a novel dexamethasone-heparin-double-coated stent for inhibition of artery restenosis and thrombosis.

Authors:  Qing-Kui Guo; Zhi-Qian Lu; Jin-Ye Wang; Tao Li
Journal:  J Mater Sci Mater Med       Date:  2011-05-10       Impact factor: 3.896

  2 in total