Literature DB >> 1789456

Strategies for low detection limit measurements with cyclic voltammetry.

D J Wiedemann1, K T Kawagoe, R T Kennedy, E L Ciolkowski, R M Wightman.   

Abstract

Cyclic voltammetry of Nafion-coated, carbon-fiber electrodes is used to detect trace concentrations of dopamine, both in a flow injection apparatus and in the brain of an anaesthetized rat. To improve signal-to-noise ratios, the sources of noise during cyclic voltammetry have been determined and strategies have been developed to decrease the noise. With the potentiostat employed, the measured noise is comparable to that expected for Johnson noise from the feedback resistor of the current transducer. Additional noise arises from the waveform generator employed and, in some cases, line noise. Line noise is discriminated against by starting each cyclic voltammogram either in phase or 180 degrees out of phase with the line frequency. When used in vivo, additional noise also arises from the physiological activity of the animal. Detection limits are found to closely correspond to those predicted on the basis of simulation of the voltammetric shape and the measured noise. Detection limits are improved by the use of appropriate analog and digital filtering, ensemble averaging, and appropriate timing of repetitive cyclic voltammograms. The combined use of these techniques enables the in vivo detection of approximately 100 nM of dopamine with a signal-to-noise ratio of 25.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1789456     DOI: 10.1021/ac00024a030

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  11 in total

1.  Preferential increases in nucleus accumbens dopamine after systemic cocaine administration are caused by unique characteristics of dopamine neurotransmission.

Authors:  Q Wu; M E Reith; M J Kuhar; F I Carroll; P A Garris
Journal:  J Neurosci       Date:  2001-08-15       Impact factor: 6.167

2.  In vivo comparison of norepinephrine and dopamine release in rat brain by simultaneous measurements with fast-scan cyclic voltammetry.

Authors:  Jinwoo Park; Pavel Takmakov; R Mark Wightman
Journal:  J Neurochem       Date:  2011-10-20       Impact factor: 5.372

3.  Are striatal tyrosine hydroxylase interneurons dopaminergic?

Authors:  Harry S Xenias; Osvaldo Ibáñez-Sandoval; Tibor Koós; James M Tepper
Journal:  J Neurosci       Date:  2015-04-22       Impact factor: 6.167

4.  Development of the Mayo Investigational Neuromodulation Control System: toward a closed-loop electrochemical feedback system for deep brain stimulation.

Authors:  Su-Youne Chang; Christopher J Kimble; Inyong Kim; Seungleal B Paek; Kenneth R Kressin; Joshua B Boesche; Sidney V Whitlock; Diane R Eaker; Aimen Kasasbeh; April E Horne; Charles D Blaha; Kevin E Bennet; Kendall H Lee
Journal:  J Neurosurg       Date:  2013-10-11       Impact factor: 5.115

5.  Nafion-CNT coated carbon-fiber microelectrodes for enhanced detection of adenosine.

Authors:  Ashley E Ross; B Jill Venton
Journal:  Analyst       Date:  2012-05-18       Impact factor: 4.616

6.  Interaction between diffusion and Michaelis-Menten uptake of dopamine after iontophoresis in striatum.

Authors:  C Nicholson
Journal:  Biophys J       Date:  1995-05       Impact factor: 4.033

7.  In vivo voltammetric measurement of evoked extracellular dopamine in the rat basolateral amygdaloid nucleus.

Authors:  P A Garris; R M Wightman
Journal:  J Physiol       Date:  1994-07-15       Impact factor: 5.182

8.  A simple way to build a grinder for carbon-fibre electrodes for amperometry or voltammetry.

Authors:  Ricardo Borges; Jésica Díaz; Marcial Camacho; José D Machado
Journal:  Pflugers Arch       Date:  2005-05-14       Impact factor: 3.657

9.  Functional reorganization of the presynaptic dopaminergic terminal in parkinsonism.

Authors:  B P Bergstrom; S G Sanberg; M Andersson; J Mithyantha; F I Carroll; P A Garris
Journal:  Neuroscience       Date:  2011-07-20       Impact factor: 3.590

10.  Flexible software platform for fast-scan cyclic voltammetry data acquisition and analysis.

Authors:  Elizabeth S Bucher; Kenneth Brooks; Matthew D Verber; Richard B Keithley; Catarina Owesson-White; Susan Carroll; Pavel Takmakov; Collin J McKinney; R Mark Wightman
Journal:  Anal Chem       Date:  2013-10-11       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.