Literature DB >> 1789455

Enzyme-modified organic conducting salt microelectrode.

J L Kawagoe1, D E Niehaus, R M Wightman.   

Abstract

A miniaturized enzyme-modified electrode has been constructed and evaluated. The tip of a capillary-encased, carbon-fiber electrode is recessed, and tetrathiafulvalene-tetracyanoquinodimethane crystals are electrochemically deposited in the recessed tip. Flavoenzymes are placed in the recess by cross-linking with glutaraldehyde. The specific enzymes used are glucose oxidase to form a microbiosensor for glucose, and a combination of acetylcholine esterase and choline oxidase to form a microbiosensor for acetylcholine. The sensor is operated in an amperometric mode with Eapp = 150 mV versus a sodium saturated calomel electrode, and the response appears to be limited by the kinetics of the enzyme reaction. The effective maximum current density for the glucose electrode is greater than 600 microA/cm2. At low concentrations of glucose, oxygen provides a significant interference by attenuating the signal. The device is simple to prepare and has a rapid response time. Interference from ascorbate has been significantly reduced by the design and by addition of a layer of ascorbate oxidase. Although not yet suitable for use in tissue, the biosensors are suitable for detection in situations where oxygen concentrations do not frequently change.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1789455     DOI: 10.1021/ac00024a029

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Nanopipet-Based Liquid-Liquid Interface Probes for the Electrochemical Detection of Acetylcholine, Tryptamine, and Serotonin via Ionic Transfer.

Authors:  Michelle L Colombo; Jonathan V Sweedler; Mei Shen
Journal:  Anal Chem       Date:  2015-04-30       Impact factor: 6.986

Review 2.  What do phasic cholinergic signals do?

Authors:  Martin Sarter; Cindy Lustig; Anne S Berry; Howard Gritton; William M Howe; Vinay Parikh
Journal:  Neurobiol Learn Mem       Date:  2016-02-18       Impact factor: 2.877

3.  Detection of evoked acetylcholine release in mouse brain slices.

Authors:  R Asri; B O'Neill; J C Patel; K A Siletti; M E Rice
Journal:  Analyst       Date:  2016-11-14       Impact factor: 4.616

4.  Electrochemical nanoprobes for the chemical detection of neurotransmitters.

Authors:  Mei Shen; Michelle L Colombo
Journal:  Anal Methods       Date:  2015-09-07       Impact factor: 2.896

5.  An update of the classical and novel methods used for measuring fast neurotransmitters during normal and brain altered function.

Authors:  Victor Hugo Cifuentes Castro; Carmen Lucía López Valenzuela; Juan Carlos Salazar Sánchez; Kenia Pardo Peña; Silvia J López Pérez; Jorge Ortega Ibarra; Alberto Morales Villagrán
Journal:  Curr Neuropharmacol       Date:  2014-12       Impact factor: 7.363

  5 in total