Literature DB >> 1789441

Electrospray and tandem mass spectrometric characterization of acylglycerol mixtures that are dissolved in nonpolar solvents.

K L Duffin1, J D Henion, J J Shieh.   

Abstract

This paper presents electrospray mass spectrometric analysis of mixtures containing monoglycerides, diglycerides, and triglycerides. Sample compounds were dissolved in concentrations of 1-50 pmol/microL in chloroform:methanol (70:30, v:v), which was modified by the addition of alkall-metal or ammonium salts or by addition of formic acid to favor the addition of a cationic species to the sample molecules. Electrospray mass spectrometric analysis of acylglycerol standards yielded positive-ion current signals for (M + Na)+ or (M + NH4)+ of all the species that were present at low picomole per microliter concentrations with no fragmentation. For equimolar concentrations of these sample compounds, there was a general decrease in ion current response as the analyte polarity decreased. Therefore, acylglycerols that contained unsaturated fatty acid chains were observed to exhibit a response in the mass spectrum greater than those with saturated chains, and ion signals resulting from the molecular adduct ions of monoglycerides were more abundant than those of diglycerides, which were more abundant than those of triglycerides in the mass spectrum. Electrospray mass spectrometric analysis of an unknown lipid material recovered from a mammalian cell culture reactor revealed a mixture of triglycerides containing mostly C14, C16, and C18 fatty acids with varying degrees of unsaturation. The results obtained by electrospray mass spectrometry compared favorably to those obtained by gas chromatography after saponification and methylation of fatty acid components of the triglycerides. MS/MS fragmentation of sodiated acylglycerols required a dissociation energy significantly greater than that required for fragmentation of ammoniated acylglycerols, so MS/MS characterization of acylglycerols was generally performed on the ammoniated compounds.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1789441     DOI: 10.1021/ac00017a023

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  39 in total

1.  High-throughput sample preparation and analysis using 96-well membrane solid-phase extraction and liquid chromatography-tandem mass spectrometry for the determination of steroids in human urine.

Authors:  G Rule; J Henion
Journal:  J Am Soc Mass Spectrom       Date:  1999-12       Impact factor: 3.109

2.  Determining the relative amounts of positional isomers in complex mixtures of triglycerides using reversed-phase high-performance liquid chromatography-tandem mass spectrometry.

Authors:  Michael Malone; Jason J Evans
Journal:  Lipids       Date:  2004-03       Impact factor: 1.880

3.  Electrospray ionization multiple-stage linear ion-trap mass spectrometry for structural elucidation of triacylglycerols: assignment of fatty acyl groups on the glycerol backbone and location of double bonds.

Authors:  Fong-Fu Hsu; John Turk
Journal:  J Am Soc Mass Spectrom       Date:  2010-01-25       Impact factor: 3.109

4.  Regiospecific determination of short-chain triacylglycerols in butterfat by normal-phase HPLC with on-line electrospray-tandem mass spectrometry.

Authors:  P Kalo; A Kemppinen; V Ollilainen; A Kuksis
Journal:  Lipids       Date:  2004-09       Impact factor: 1.880

Review 5.  Mass spectrometry-based metabolomics.

Authors:  Katja Dettmer; Pavel A Aronov; Bruce D Hammock
Journal:  Mass Spectrom Rev       Date:  2007 Jan-Feb       Impact factor: 10.946

6.  Paper spray ionization of polar analytes using non-polar solvents.

Authors:  Anyin Li; He Wang; Zheng Ouyang; R Graham Cooks
Journal:  Chem Commun (Camb)       Date:  2011-02-01       Impact factor: 6.222

7.  Identification of components in waste streams by electrospray and tandem mass spectrometry.

Authors:  B M Hughes; D E McKenzie; K L Duffin
Journal:  J Am Soc Mass Spectrom       Date:  1993-07       Impact factor: 3.109

8.  High-resolution triacylglycerol mixture analysis using high-temperature gas chromatography / mass spectrometry with a polarizable stationary phase, negative ion chemical ionization, and mass-resolved chromatography.

Authors:  R P Evershed
Journal:  J Am Soc Mass Spectrom       Date:  1996-04       Impact factor: 3.109

9.  Atmospheric pressure covalent adduct chemical ionization tandem mass spectrometry for double bond localization in monoene- and diene-containing triacylglycerols.

Authors:  Yichuan Xu; J Thomas Brenna
Journal:  Anal Chem       Date:  2007-02-06       Impact factor: 6.986

10.  Imaging of Triglycerides in Tissues Using Nanospray Desorption Electrospray Ionization (Nano-DESI) Mass Spectrometry.

Authors:  Daisy Unsihuay; Jiamin Qiu; Sneha Swaroop; Konstantin O Nagornov; Anton N Kozhinov; Yury O Tsybin; Shihuan Kuang; Julia Laskin
Journal:  Int J Mass Spectrom       Date:  2019-11-27       Impact factor: 1.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.