Literature DB >> 17893279

Twenty-five-year experience with the Medtronic-Hall valve prosthesis in the aortic position: a follow-up cohort study of 816 consecutive patients.

Jan L Svennevig1, Michel Abdelnoor, Sigurd Nitter-Hauge.   

Abstract

BACKGROUND: The Medtronic-Hall valve was developed and for the first time implanted in Oslo, Norway, in 1977. A total of 1104 patients received this valve at Rikshospitalet from 1977 to 1987. In the present study, we followed up on all 816 patients undergoing aortic valve replacement over a 25-year period. METHODS AND
RESULTS: This is a retrospective cohort analysis of 816 consecutive patients undergoing aortic valve replacement with the Medtronic-Hall valve at Rikshospitalet, Oslo, Norway, from 1977 to 1987. All patients were contacted by means of questionnaires or telephone. Data were checked against hospital databases and medical records. Date of death was verified by the Norwegian civil registry. Follow-up was 99.6% complete. Survival analysis included operative deaths as well as late deaths. Survival at 25 years was 24.9%. No mechanical failures were found. Valve thrombosis was seen in 4 patients, in 1 case combined with pannus formation. Small valves (20 mm to 21 mm) were associated with reduced survival; however, when controlled for the confounding effects of age and gender, valve size did not remain a significant risk factor. Patient-related factors were important: Older age, female gender, and the need for concomitant coronary artery bypass surgery significantly reduced survival, whereas surgery of the ascending aorta did not. Linearized rates of thromboembolic complications, warfarin-related bleeding, and endocarditis were 1.5%, 0.7%, and 0.16%/patient-year, respectively. At follow-up, 79% of the patients were in New York Heart Association classes I to II.
CONCLUSIONS: This study confirms the excellent long-term outcome for patients with Medtronic-Hall valves in the aortic position.

Entities:  

Mesh:

Year:  2007        PMID: 17893279     DOI: 10.1161/CIRCULATIONAHA.106.677773

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  3 in total

1.  Treatment outcomes in patients with non-infectious aortic valvulitis undergoing aortic valve replacement: implication for the treatment of aortic valve involvement in Behcet's disease.

Authors:  Joong Kyong Ahn; Hyungjin Kim; Jaejoon Lee; Pyo-Won Park; Chan Hong Jeon; Eun-Mi Koh; Hoon-Suk Cha
Journal:  Rheumatol Int       Date:  2009-01-25       Impact factor: 2.631

2.  Tunable Elastomers with an Antithrombotic Component for Cardiovascular Applications.

Authors:  Alexander M Stahl; Yunzhi Peter Yang
Journal:  Adv Healthc Mater       Date:  2018-05-31       Impact factor: 9.933

3.  Prognosis after surgical replacement with a bioprosthetic aortic valve in patients with severe symptomatic aortic stenosis: systematic review of observational studies.

Authors:  Farid Foroutan; Gordon H Guyatt; Kathleen O'Brien; Eva Bain; Madeleine Stein; Sai Bhagra; Daegan Sit; Rakhshan Kamran; Yaping Chang; Tahira Devji; Hassan Mir; Veena Manja; Toni Schofield; Reed A Siemieniuk; Thomas Agoritsas; Rodrigo Bagur; Catherine M Otto; Per O Vandvik
Journal:  BMJ       Date:  2016-09-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.