Literature DB >> 17889772

Intraocular pressure rise after primary posterior continuous curvilinear capsulorhexis with a fixed dorzolamide-timolol combination: randomized safety study with intraindividual comparison using an angulated and a nonangulated intraocular lens.

Matthias G Wirtitsch1, Rupert Menapace, Michael Georgopoulos, Georg Rainer, Wolf Buehl, Harald Heinzl.   

Abstract

PURPOSE: To assess the safety, in terms of the intraocular pressure (IOP), of cataract surgery with primary posterior continuous curvilinear capsulorhexis (PPCCC) and a postoperative dose of a fixed dorzolamide-timolol combination and evaluate the effect of intraocular lens (IOL) haptic angulation.
SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
METHODS: In this prospective randomized double-masked bilateral study, 88 eyes of 44 consecutive patients with age-related cataract were included in an intraindividual comparison study. All patients had standardized cataract surgery with PPCCC and IOL implantation in the capsular bag followed by a postoperative dose of a fixed dorzolamide-timolol combination. Patients were randomly assigned to receive an ACR6D SE IOL (Laboratoires Cornéal) in 1 eye and a Centerflex (C-flex) 570C IOL (Rayner Surgical GmbH) in the contralateral eye. The IOP was measured at baseline and postoperatively at 6 and 24 hours as well as 1 week.
RESULTS: Intraindividual comparison showed statistically significantly higher IOP measurements in the C-flex 570C nonangulated IOL group than in the ACR6D SE angulated IOL group at 24 hours (P = .003) and 1 week (P = .043). The highest IOP spikes (34 mm Hg) were at 6 hours in 2 eyes with a C-flex 570C IOL. The ACR6D SE group had statistically significant changes in IOP between preoperative and all postoperative time points. In the C-flex 570C group, the only statistically significant change in IOP was between preoperatively and 6 hours postoperatively.
CONCLUSIONS: Cataract surgery with PPCCC was safe in terms of the postoperative IOP course. Haptic angulation slightly decreased the overall IOP rise and the incidence of IOP rises above 30 mm Hg.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17889772     DOI: 10.1016/j.jcrs.2007.05.039

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  2 in total

1.  Posterior optic buttonholing prevents intraocular pressure peaks after cataract surgery with primary posterior capsulorhexis.

Authors:  Eva Stifter; Rupert Menapace; Katharina Kriechbaum; Alexandra Luksch
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-07-22       Impact factor: 3.117

Review 2.  [After-cataract following intraocular lens implantation. Part II: prevention with alternative implants and techniques].

Authors:  R Menapace
Journal:  Ophthalmologe       Date:  2007-04       Impact factor: 1.059