Noninvasive measurement of cardiac output in hemodialysis patients by task force monitor: a comparison with the Transonic System.

Thomas M Kitzler1, Olga Sergeyeva, Alice Morris, Falko Skrabal, Peter Kotanko, Nathan W Levin.   

Abstract

Cardiovascular disease is the leading cause of morbidity and mortality in maintenance hemodialysis (MHD) patients. The Transonic (TRS; Transonic Systems, Ithaca, NY) device is frequently used for determination of cardiac output (CO) by an indicator dilution technique. The Task Force Monitor (TFM; CN Systems, Graz, Austria) has gained attention as noninvasive tool for continuous beat-to-beat assessment of cardiovascular variables, including CO by impedance cardiography. Despite its use in cardiology and intensive care settings, the TFM has yet not been validated in dialysis patients. This study compares CO measurements in 12 MHD patients by TFM and TRS. Bland-Altman and regression analysis were used. CO was measured simultaneously by TRS and TFM. Average CO was 5.4 L/min by TRS and 5.0 L/min by TFM, respectively. Bland-Altman analysis revealed no significant systematic differences between the two methods (mean difference: 0.4 L/min; SD: 0.6; p > 0.05). Linear regression analysis showed significant correlation between both techniques (r = 0.802, p = 0.002). The SD of mean individual CO values was 1.1 L/min with TRS and 0.8 L/min with TFM, respectively.CO measured by TFM and TRS does not differ significantly, thus making the TFM an attractive noninvasive tool for the continuous beat-to-beat assessment of CO in MHD patients.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17885328     DOI: 10.1097/MAT.0b013e31812e6a90

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  2 in total

1.  Severity of cardiac impairment in the early stage of community-acquired sepsis determines worse prognosis.

Authors:  Joachim Wilhelm; Stefan Hettwer; Markus Schuermann; Silke Bagger; Franziska Gerhardt; Sandra Mundt; Susanne Muschik; Julia Zimmermann; Sebastian Bubel; Mroawan Amoury; Thomas Kloess; Rainer Finke; Harald Loppnow; Ursula Mueller-Werdan; Henning Ebelt; Karl Werdan
Journal:  Clin Res Cardiol       Date:  2013-06-06       Impact factor: 5.460

2.  Reduced systemic vascular resistance is the underlying hemodynamic mechanism in nitrate-stimulated vasovagal syncope during head-up tilt-table test.

Authors:  Byung Gyu Kim; Sung Woo Cho; Hye Young Lee; Deok Hee Kim; Young Sup Byun; Choong Won Goh; Kun Joo Rhee; Byung Ok Kim
Journal:  J Arrhythm       Date:  2015-04-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.