Literature DB >> 17885194

Large-vessel distensibility measurement with electrocardiographically gated multidetector CT: phantom study and initial experience.

Jie Zhang1, Joel G Fletcher, Terri J Vrtiska, Armando Manduca, Jess L Thompson, Madhavan L Raghavan, Robert J Wentz, Cynthia H McCollough.   

Abstract

The purpose of this study was to prospectively examine vessel distensibility measurements by using electrocardiographically gated multidetector computed tomography (CT) in a phantom compared with measurements by using a digital camera and to examine feasibility in humans. Large-vessel phantoms were constructed, using a pulsatile flow pump, and absolute diameter and percentage diameter changes during pulsation were measured. After institutional review board approval and patient consent were obtained, the abdominal aorta of four patients was scanned with an electrocardiographically gated CT protocol. The mean difference in percentage diameter change between CT and optical measurements for the phantom ranged from -0.47% to 0.14%. The range of area changes in five locations along the abdominal aorta in four patients was 2.97%-37.16%. Findings of this study indicate that electrocardiographically gated CT angiography data reconstructed across cardiac phases permit measurements of large-vessel distensibility in a phantom model and that vessel distensibility measurement in humans may be possible. Copyright (c) RSNA, 2007.

Entities:  

Mesh:

Year:  2007        PMID: 17885194     DOI: 10.1148/radiol.2451060530

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

Review 1.  Imaging of patients with congenital heart disease.

Authors:  Arno A W Roest; Albert de Roos
Journal:  Nat Rev Cardiol       Date:  2011-11-01       Impact factor: 32.419

2.  Assessment of thoracic aortic elasticity: a preliminary study using electrocardiographically gated dual-source CT.

Authors:  Ning Li; Thomas Beck; Jiuhong Chen; Christina Biermann; Lijun Guo; Haitao Sun; Fei Gao; Cheng Liu
Journal:  Eur Radiol       Date:  2011-02-15       Impact factor: 5.315

3.  Aortic distensibility and its relationship to coronary and thoracic atherosclerosis plaque and morphology by MDCT: insights from the ROMICAT Trial.

Authors:  Emily Siegel; Wai-Ee Thai; Tust Techasith; Gyongyi Major; Jackie Szymonifka; Ahmed Tawakol; John T Nagurney; Udo Hoffmann; Quynh A Truong
Journal:  Int J Cardiol       Date:  2012-05-10       Impact factor: 4.164

4.  Human CT Measurements of Structure/Electrode Position Changes During Respiration with Electrical Impedance Tomography.

Authors:  Jie Zhang; Lihong Qin; Tadashi Allen; Robert P Patterson
Journal:  Open Biomed Eng J       Date:  2013-11-15

5.  Quantitative Aortic Distensibility Measurement Using CT in Patients with Abdominal Aortic Aneurysm: Reproducibility and Clinical Relevance.

Authors:  Yunfei Zha; Gongling Peng; Liang Li; Chunying Yang; Xuesong Lu; Zhoufeng Peng
Journal:  Biomed Res Int       Date:  2017-04-18       Impact factor: 3.411

6.  Analysis of elasticity characteristics of ascending aorta, descending aorta and pulmonary artery using 640 slice-volume CT.

Authors:  Fei Yang; Dawei Wang; Huaijun Liu; Xiaolong Zhu; Dianjun Zou; Xiaocan Wang; Zhenshun Hu; Mengmeng Ji; Shujun Cui; Yue Xiang Zhu; Jing Wen
Journal:  Medicine (Baltimore)       Date:  2018-06       Impact factor: 1.889

7.  Standard of practice for the endovascular treatment of thoracic aortic aneurysms and type B dissections.

Authors:  Fabrizio Fanelli; Michael D Dake
Journal:  Cardiovasc Intervent Radiol       Date:  2009-08-18       Impact factor: 2.740

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.