The influence of the pulsatility of the blood flow on the extent of platelet adhesion.

Xiao Min Zhao1, Ya Ping Wu, Hong Xin Cai, Ran Wei, Ton Lisman, Ji Ju Han, Zuo Li Xia, Philip G de Groot.   

Abstract

A new improved flow system was developed to study the influence of blood flow pulsatility on platelet adhesion on adhesive proteins and bio-medical materials. The pulsatility was introduced by changing the shear rate every 15 s in blood that was aspirated through a perfusion chamber by a syringe pump. The advantage of this new system is that it avoids system related platelet activation. At steady low shear rate (300/s) after 5 min a collagen type III surface was covered for 24.2+/-3.8% with platelets. At steady high shear rate (1300/s) platelet coverage to collagen was 48.8+/-6.8%. When pulsatility was introduced by changing the shear rate was every 15 s form 300/s to 1300/s and vice-versa, platelet coverage after 5 min was increased to 60.4+/-4.0% (p<0.001). After 5 min perfusion samples were taken from the perfusate and the extent of platelet activation was measured. The significant difference in surface expression of P-selectin on platelets is only seen when comparing pulse flow with control (no flow). We concluded that a significant increase in platelet activation during blood pulsatile flow compared with steady flow, which results in an increased platelet adhesion to collagen.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17884149     DOI: 10.1016/j.thromres.2007.07.013

Source DB:  PubMed          Journal:  Thromb Res        ISSN: 0049-3848            Impact factor:   3.944


  4 in total

1.  State of the art in platelet function testing.

Authors:  Beate E Kehrel; Martin F Brodde
Journal:  Transfus Med Hemother       Date:  2013-03-18       Impact factor: 3.747

2.  Sources of variability in platelet accumulation on type 1 fibrillar collagen in microfluidic flow assays.

Authors:  Keith B Neeves; Abimbola A Onasoga; Ryan R Hansen; Jessica J Lilly; Diana Venckunaite; Meghan B Sumner; Andrew T Irish; Gary Brodsky; Marilyn J Manco-Johnson; Jorge A Di Paola
Journal:  PLoS One       Date:  2013-01-23       Impact factor: 3.240

Review 3.  Obstacles in haemocompatibility testing.

Authors:  W van Oeveren
Journal:  Scientifica (Cairo)       Date:  2013-05-07

4.  Increased erythrocyte adhesion to VCAM-1 during pulsatile flow: Application of a microfluidic flow adhesion bioassay.

Authors:  Jennell White; Moira Lancelot; Sharada Sarnaik; Patrick Hines
Journal:  Clin Hemorheol Microcirc       Date:  2015       Impact factor: 2.375

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.