Literature DB >> 17884130

Effect of pipe corrosion scales on chlorine dioxide consumption in drinking water distribution systems.

Zhe Zhang1, Janet E Stout, Victor L Yu, Radisav Vidic.   

Abstract

Previous studies showed that temperature and total organic carbon in drinking water would cause chlorine dioxide (ClO(2)) loss in a water distribution system and affect the efficiency of ClO(2) for Legionella control. However, among the various causes of ClO(2) loss in a drinking water distribution system, the loss of disinfectant due to the reaction with corrosion scales has not been studied in detail. In this study, the corrosion scales from a galvanized iron pipe and a copper pipe that have been in service for more than 10 years were characterized by energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). The impact of these corrosion scale materials on ClO(2) decay was investigated in de-ionized water at 25 and 45 degrees C in a batch reactor with floating glass cover. ClO(2) decay was also investigated in a specially designed reactor made from the iron and copper pipes to obtain more realistic reaction rate data. Goethite (alpha-FeOOH) and magnetite (Fe(3)O(4)) were identified as the main components of iron corrosion scale. Cuprite (Cu(2)O) was identified as the major component of copper corrosion scale. The reaction rate of ClO(2) with both iron and copper oxides followed a first-order kinetics. First-order decay rate constants for ClO(2) reactions with iron corrosion scales obtained from the used service pipe and in the iron pipe reactor itself ranged from 0.025 to 0.083 min(-1). The decay rate constant for ClO(2) with Cu(2)O powder and in the copper pipe reactor was much smaller and it ranged from 0.0052 to 0.0062 min(-1). Based on these results, it can be concluded that the corrosion scale will cause much more significant ClO(2) loss in corroded iron pipes of the distribution system than the total organic carbon that may be present in finished water.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17884130     DOI: 10.1016/j.watres.2007.07.054

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  6 in total

1.  Influence of Metal Concentration and Plumbing Materials on Legionella Contamination.

Authors:  Anita Rakić; Darija Vukić Lušić; Anamarija Jurčev Savičević
Journal:  Microorganisms       Date:  2022-05-19

2.  Flow evaluation of the leaching hazardous materials from spent nickel-cadmium batteries discarded in different water surroundings.

Authors:  Xingmei Guo; Yan Song; Junmin Nan
Journal:  Environ Sci Pollut Res Int       Date:  2017-12-07       Impact factor: 4.223

3.  Equilibrium and kinetic modeling of iron adsorption and the effect by chloride, sulfate, and hydroxyl: evaluation of PVC-U drinking pipes.

Authors:  Jia -Ying Wang; Shu-Ping Li; Kun-Lun Xin; Tao Tao
Journal:  Environ Sci Pollut Res Int       Date:  2016-09-15       Impact factor: 4.223

4.  Effects of Sulfate, Chloride, and Bicarbonate on Iron Stability in a PVC-U Drinking Pipe.

Authors:  Jiaying Wang; Tao Tao; Hexiang Yan
Journal:  Int J Environ Res Public Health       Date:  2017-06-19       Impact factor: 3.390

5.  Chlorine Dioxide Degradation Issues on Metal and Plastic Water Pipes Tested in Parallel in a Semi-Closed System.

Authors:  Alberto Vertova; Alessandro Miani; Giordano Lesma; Sandra Rondinini; Alessandro Minguzzi; Luigi Falciola; Marco Aldo Ortenzi
Journal:  Int J Environ Res Public Health       Date:  2019-11-19       Impact factor: 3.390

6.  Chlorine Reduction Kinetics and its Mass Balance in Copper Premise Plumbing Systems During Corrosion Events.

Authors:  Ignacio T Vargas; Javiera M Anguita; Pablo A Pastén; Gonzalo E Pizarro
Journal:  Materials (Basel)       Date:  2019-11-08       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.