Literature DB >> 17882037

Magnetic resonance cisternography: comparison between 3-dimensional driven equilibrium with sensitivity encoding and 3-dimensional balanced fast-field echo sequences with sensitivity encoding.

Na Young Jung1, Won-Jin Moon, Min Hee Lee, Eun Chul Chung.   

Abstract

PURPOSE: To assess the detectability of the inner ear structures using both 3-dimensional (3D) balanced fast-field echo (bFFE) and 3D driven equilibrium (DRIVE) sequences in conjunction with parallel imaging and to compare the image quality of those sequences.
MATERIALS AND METHODS: Thirty-eight healthy volunteers were examined using a 1.5-T magnetic resonance unit. The 3D bFFE and the 3D DRIVE sequences were compared. The relative contrast between the cranial nerves and the cisternal space was calculated. The detectability of the cranial nerves and the cochlear and semicircular canals was graded on a 3-point scale (1, poor; 2, fair; 3, excellent). RESULT: The relative contrast for the cranial nerve in 3D bFFE and 3D DRIVE was 4.31 +/- 1.53 and 5.73 +/- 4.60, respectively. The 2.5 turns of the cochlea, spiral lamina, and all 3 semicircular canals were better visualized using the 3D DRIVE.
CONCLUSION: The 3D DRIVE is superior to the 3D bFFE in evaluation of the structures of the inner ear.

Entities:  

Mesh:

Year:  2007        PMID: 17882037     DOI: 10.1097/rct.0b013e31809861fb

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  9 in total

1.  MR imaging of congenital or developmental neuropathic strabismus: common and uncommon findings.

Authors:  E Kim; J H Kim; J M Hwang; B S Choi; C Jung
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-17       Impact factor: 3.825

Review 2.  [Anatomy of the skull base and the cranial nerves in slice imaging].

Authors:  A Bink; J Berkefeld; F Zanella
Journal:  Radiologe       Date:  2009-07       Impact factor: 0.635

3.  Signal intensity change of the labyrinth in patients with surgically confirmed or radiologically diagnosed vestibular schwannoma on isotropic 3D fluid-attenuated inversion recovery MR imaging at 3 T.

Authors:  In Ho Lee; Hyung-Jin Kim; Won Ho Chung; Eunhee Kim; Jung Won Moon; Sung Tae Kim; Keon Ha Kim; Pyoung Jeon; Hong Sik Byun
Journal:  Eur Radiol       Date:  2009-11-07       Impact factor: 5.315

4.  Optic chiasmal edema observed on T2-weighted MR images: a reversible finding in obstructive hydrocephalus.

Authors:  Takashi Hiyama; Tomohiko Masumoto; Masanari Shiigai; Hiroyoshi Akutsu; Akira Matsumura; Manabu Minami
Journal:  Jpn J Radiol       Date:  2015-01-29       Impact factor: 2.374

5.  Preoperative detection of the facial nerve by high-field magnetic resonance imaging in patients with vestibular schwannoma.

Authors:  Tomoaki Nakai; Hirotaka Yamamoto; Kazuhiro Tanaka; Junji Koyama; Atsushi Fujita; Masaaki Taniguchi; Kohkichi Hosoda; Eiji Kohmura
Journal:  Neuroradiology       Date:  2013-02-15       Impact factor: 2.804

6.  Radiosurgical decompression for benign perioptic tumors causing compressive cranial neuropathies: a feasible alternative to microsurgery?

Authors:  Eun Jung Lee; Young Hyun Cho; KyoungJun Yoon; Byungchul Cho; Eun Suk Park; Chang Jin Kim; Sung Woo Roh
Journal:  J Neurooncol       Date:  2016-09-06       Impact factor: 4.130

7.  MR imaging of the internal auditory canal and inner ear at 3T: comparison between 3D driven equilibrium and 3D balanced fast field echo sequences.

Authors:  Jun Soo Byun; Hyung Jin Kim; Yoo Jeong Yim; Sung Tae Kim; Pyoung Jeon; Keon Ha Kim; Sam Soo Kim; Yong Hwan Jeon; Jiwon Lee
Journal:  Korean J Radiol       Date:  2008 May-Jun       Impact factor: 3.500

8.  Merging images with different central frequencies reduces banding artifacts in balanced steady-state free precession magnetic resonance cisternography.

Authors:  Koji Matsumoto; Hajime Yokota; Hiroki Mukai; Yoshitada Masuda; Takashi Uno; Tosiaki Miyati
Journal:  J Appl Clin Med Phys       Date:  2018-10-05       Impact factor: 2.102

9.  A method for measuring the length of the cochlea through magnetic resonance imaging.

Authors:  Fernando Pochini Sobrinho; Paulo Roberto Lazarini; Hea Jung Yoo; Luiz de Abreu Júnior; Altino de Sá Meira
Journal:  Braz J Otorhinolaryngol       Date:  2009 Mar-Apr
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.