Genetic evolutionary taboo search for optimal marker placement in infrared patient setup.

M Riboldi1, G Baroni, M F Spadea, B Tagaste, C Garibaldi, R Cambria, R Orecchia, A Pedotti.   

Abstract

In infrared patient setup adequate selection of the external fiducial configuration is required for compensating inner target displacements (target registration error, TRE). Genetic algorithms (GA) and taboo search (TS) were applied in a newly designed approach to optimal marker placement: the genetic evolutionary taboo search (GETS) algorithm. In the GETS paradigm, multiple solutions are simultaneously tested in a stochastic evolutionary scheme, where taboo-based decision making and adaptive memory guide the optimization process. The GETS algorithm was tested on a group of ten prostate patients, to be compared to standard optimization and to randomly selected configurations. The changes in the optimal marker configuration, when TRE is minimized for OARs, were specifically examined. Optimal GETS configurations ensured a 26.5% mean decrease in the TRE value, versus 19.4% for conventional quasi-Newton optimization. Common features in GETS marker configurations were highlighted in the dataset of ten patients, even when multiple runs of the stochastic algorithm were performed. Including OARs in TRE minimization did not considerably affect the spatial distribution of GETS marker configurations. In conclusion, the GETS algorithm proved to be highly effective in solving the optimal marker placement problem. Further work is needed to embed site-specific deformation models in the optimization process.

Entities:  

Mesh:

Year:  2007        PMID: 17881802     DOI: 10.1088/0031-9155/52/19/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Selection of Fiducial Locations and Performance Metrics for Point-Based Rigid-Body Registration.

Authors:  Marek Franaszek; Geraldine S Cheok
Journal:  Precis Eng       Date:  2016-09-27       Impact factor: 3.156

2.  Optimization Model for the Distribution of Fiducial Markers in Liver Intervention.

Authors:  Qinyong Lin; Rongqian Yang; Lin Yang; Huazhou Chen; Bohan Li; Ken Cai
Journal:  J Med Syst       Date:  2020-03-09       Impact factor: 4.460

3.  Orientation Uncertainty Characteristics of Some Pose Measuring Systems.

Authors:  Marek Franaszek; Geraldine S Cheok
Journal:  Math Probl Eng       Date:  2017-12-31       Impact factor: 1.305