Literature DB >> 17879896

Tissue Doppler imaging reproducibility during exercise.

V Bougault1, S Nottin, S Noltin, G Doucende, P Obert.   

Abstract

Tissue Doppler imaging (TDI) is an echocardiographic technique used during exercising to improve the accuracy of a cardiovascular diagnostic. The validity of TDI requires its reproducibility, which has never been challenged during moderate to maximal intensity exercising. The present study was specifically designed to assess the transmitral Doppler and pulsed TDI reproducibility in 19 healthy men, who had undergone two identical semi-supine maximal exercise tests on a cycle ergometer. Systolic (S') and diastolic (E') tissue velocities at the septal and lateral walls as well as early transmitral velocities (E) were assessed during exercise up to maximal effort. The data were compared between the two tests at 40 %, 60 %, 80 % and 100 % of maximal aerobic power. Despite upper body movements and hyperventilation, good quality echocardiographic images were obtained in each case. Regardless of exercise intensity, no differences were noticed between the two tests for all measurements. The variation coefficients for Doppler variables ranged from 3 % to 9 % over the transition from rest to maximal exercise. The random measurement error was, on average, 5.8 cm/s for E' and 4.4 cm/s for S'. Overall, the reproducibility of TDI was acceptable. Tissue Doppler imaging can be used to accurately evaluate LV diastolic and/or systolic function for this range of exercise intensity.

Entities:  

Mesh:

Year:  2007        PMID: 17879896     DOI: 10.1055/s-2007-965356

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  6 in total

1.  Enhanced systolic myocardial function in elite endurance athletes during combined arm-and-leg exercise.

Authors:  Lars Carlsson; Britta Lind; Marko S Laaksonen; Bo Berglund; Lars-Åke Brodin; Hans-Christer Holmberg
Journal:  Eur J Appl Physiol       Date:  2010-11-11       Impact factor: 3.078

2.  Myocardial function and aerobic fitness in adolescent females.

Authors:  Thomas Rowland; Viswanath Unnithan; Denise Roche; Max Garrard; Kathyryn Holloway; Simon Marwood
Journal:  Eur J Appl Physiol       Date:  2011-01-20       Impact factor: 3.078

3.  Are measures of left ventricular systolic performance during low dose dobutamine stress echocardiograms repeatable over time?

Authors:  Nader H Elmayergi; Jack M Goodman; Leanna S Lee; Zion Sasson
Journal:  Int J Cardiovasc Imaging       Date:  2013-04-16       Impact factor: 2.357

4.  The Effect of a Hyperdynamic Circulation on Tissue Doppler Values: A Simulation in Young Adults during Exercise.

Authors:  Colin F Royse; Ni Ruizhi; Andrew L Huynh; Alistair G Royse
Journal:  Anesthesiol Res Pract       Date:  2011-02-17

5.  Myocardial functional responses do not contribute to maximal exercise performance in the heat.

Authors:  Denise L Smith; Jacob P DeBlois; Margaret Wharton; Thomas Rowland
Journal:  Extrem Physiol Med       Date:  2015-07-24

6.  Biventricular function in exercise during autonomic (thoracic epidural) block.

Authors:  Jeroen Wink; Paul Steendijk; Roula Tsonaka; Rob B P de Wilde; Hans J Friedericy; Jerry Braun; Bernadette Th Veering; Leon P H J Aarts; Patrick F Wouters
Journal:  Eur J Appl Physiol       Date:  2021-02-22       Impact factor: 3.078

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.