Literature DB >> 17878179

Resetting the detection level of cord blood thyroid stimulating hormone (TSH) for the diagnosis of congenital hypothyroidism.

O O Ogunkeye1, A I Roluga, F A Khan.   

Abstract

An appraisal of a 17-year primary thyroid stimulating hormone (TSH) screening programme for the detection of congenital hypothyroidism was carried out to establish the reference interval of cord blood TSH in unaffected infants; the mean cord blood TSH concentration of affected infants and the incidence of congenital hypothyroidism in the Najran province of Saudi Arabia. Our findings show a reference interval of cord blood TSH of 2.0-16.8 mU/l in unaffected infants; a mean cord blood TSH concentration of 399 mU/l in affected infants; a false positive rate for the diagnosis of at-risk infants of 1.02% and a congenital hypothyroidism incidence rate of 34/100 000 (1 : 2931) live births. These findings suggest that there is a need to reset the cord blood TSH concentration for the detection of at-risk infants. We suggest that the detection level of cord blood TSH for the recognition of at-risk infants can be set at 90 mU/l rather than the recommended level of 30 mU/l. This should reduce the false positive rate for detection of infants at risk of congenital hypothyroidism.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17878179     DOI: 10.1093/tropej/fmm082

Source DB:  PubMed          Journal:  J Trop Pediatr        ISSN: 0142-6338            Impact factor:   1.165


  5 in total

1.  Neonatal thyroid status in an area of iodine sufficiency.

Authors:  F Azizi; M S Hosseini; A Amouzegar; M Tohidi; E Ainy
Journal:  J Endocrinol Invest       Date:  2010-10-15       Impact factor: 4.256

2.  Establishment of biochemistry reference values for healthy Tanzanian infants, children and adolescents in Kilimanjaro Region.

Authors:  Ann M Buchanan; Suzanne P Fiorillo; Michael W Omondi; Coleen K Cunningham; John A Crump
Journal:  Trop Med Int Health       Date:  2015-08-25       Impact factor: 2.622

3.  Reference Standards for Newborn Screening of Metabolic Disorders by Tandem Mass Spectrometry: A Nationwide Study on Millions of Chinese Neonatal Populations.

Authors:  Falin He; Rulai Yang; Xinwen Huang; Yaping Tian; Xiaofang Pei; Mary Kathryn Bohn; Lin Zou; Yan Wang; Haibo Li; Ting Wang; Maosheng Gu; Tao Jiang; Xigui Chen; Hui Zou; Hongwei Wei; Weibing Tian; Tian Tang; Khosrow Adeli; Zhiguo Wang
Journal:  Front Mol Biosci       Date:  2021-12-16

Review 4.  Worldwide Recall Rate in Newborn Screening Programs for Congenital Hypothyroidism.

Authors:  Ladan Mehran; Davood Khalili; Shahin Yarahmadi; Atieh Amouzegar; Mehdi Mojarrad; Nasrin Ajang; Fereidoun Azizi
Journal:  Int J Endocrinol Metab       Date:  2017-06-25

5.  Incidental screen positive findings in a prospective cohort study in Matlab, Bangladesh: insights into expanded newborn screening for low-resource settings.

Authors:  Malia S Q Murphy; Pranesh Chakraborty; Jesmin Pervin; Anisur Rahman; Lindsay A Wilson; Monica Lamoureux; Kathryn Denize; Matthew Henderson; Steve Hawken; Beth K Potter; Julian Little; Kumanan Wilson
Journal:  Orphanet J Rare Dis       Date:  2019-01-30       Impact factor: 4.123

  5 in total