Acoustic transmission of the aortic component of the second heart sound within the ascending aorta of dogs.

L G Durand1, Y E Langlois, T Lanthier, R Chiarella, P Coppens, S Carioto, S Bertrand-Bradley.   

Abstract

The spectral characteristics of the acoustic transmission of the aortic component of the second heart sound within the ascending aorta was studied using a Millar dual-micromanometer catheter. The tip micromanometer was located close to the aortic valve leaflets while the second micromanometer was located 3 cm above the aortic valve. The frequency response of the transmission properties (amplitude and phase) of the blood and the aortic wall was modelled by an equivalent acoustic transmission system. The signal recorded by the tip micromanometer located near the aortic valve was considered to be the input signal of the equivalent system and the signal recorded by the second micromanometer was used as the output signal. Results of the spectral analysis of the input and output signals show that the acoustic transmissibility of blood in the ascending aorta is high at 20 Hz (the attenuation is negligible). Between 20 and 60 Hz, the transmissibility decreases at a rate of -3 dB per octave while between 60 and 120 Hz it decreases at a rate of -14 dB per octave. Above 120 Hz the transmissibility is low and the resulting attenuation is greater than 20 dB. The phase of the transfer function is shifted by -60 degrees at 20 Hz and decreases at a mean rate of -2.0 degrees Hz-1 between 20 and 100 Hz and -0.75 degrees Hz-1 up to 400 Hz. The phase velocity of the sound transmission is relatively constant (5.5 ms-1) between 40 and 100 Hz and increases up to 9 ms-1 at 300 Hz.

Entities:  

Mesh:

Year:  1991        PMID: 1787753     DOI: 10.1007/bf02441658

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  Conduction of cardiovascular sound along arteries.

Authors:  J J FARBER; J H PURVIS
Journal:  Circ Res       Date:  1963-03       Impact factor: 17.367

2.  The forces needed to evoke sounds from cardiac tissues, and the attenuation of heart sounds.

Authors:  W DOCK
Journal:  Circulation       Date:  1959-03       Impact factor: 29.690

3.  Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs. Part 3. Effects of altering heart rate and P-R interval.

Authors:  L G Durand; Y E Langlois; T Lanthier; R Chiarella; P Coppens; S Carioto; S Bertrand-Bradley
Journal:  Med Biol Eng Comput       Date:  1990-09       Impact factor: 2.602

4.  Physics of vibrations in living tissues.

Authors:  H E V GIERKE; H L OESTREICHER; E K FRANKE; H O PARRACK; W W V WITTERN
Journal:  J Appl Physiol       Date:  1952-06       Impact factor: 3.531

5.  Dispersion and attenuation of small artificial pressure waves in the canine aorta.

Authors:  M Anliker; M B Histand; E Ogden
Journal:  Circ Res       Date:  1968-10       Impact factor: 17.367

6.  Significance of momentary pressure changes during isovolumic relaxation.

Authors:  H N Sabbah; F Khaja; D T Anbe; P D Stein
Journal:  Cathet Cardiovasc Diagn       Date:  1978

7.  Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs. Part 2. Effects of neuromuscular blockade, sternotomy and pacemaker control, and a two-week recovery period.

Authors:  L G Durand; Y E Langlois; T Lanthier; R Chiarella; P Coppens; S Carioto; S Bertrand-Bradley
Journal:  Med Biol Eng Comput       Date:  1990-07       Impact factor: 2.602

8.  Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs. Part 1. Modelling the heart/thorax acoustic system.

Authors:  L G Durand; Y E Langlois; T Lanthier; R Chiarella; P Coppens; S Carioto; S Bertrand-Bradley
Journal:  Med Biol Eng Comput       Date:  1990-07       Impact factor: 2.602

9.  Mechanical vibration transmission characteristics of the left ventricle: implications with regard to auscultation and phonocardiography.

Authors:  D Smith; T Ishimitsu; E Craige
Journal:  J Am Coll Cardiol       Date:  1984-09       Impact factor: 24.094

  9 in total
  1 in total

1.  Development of a cardiac acoustic mapping system.

Authors:  M Cozic; L G Durand; R Guardo
Journal:  Med Biol Eng Comput       Date:  1998-07       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.