Literature DB >> 17877418

Disposable electrochemical immunosensor diagnosis device based on nanoparticle probe and immunochromatographic strip.

Guodong Liu1, Ying-Ying Lin, Jun Wang, Hong Wu, Chien M Wai, Yuehe Lin.   

Abstract

We describe a disposable electrochemical immunosensor diagnosis device that integrates the immunochromatographic strip technique with an electrochemical immunoassay and exploits quantum dot (QD, CdS@ZnS) as labels for amplifying signal output. The device takes advantage of the speed and low cost of the conventional immunochromatographic strip test and the high sensitivity of the nanoparticle-based electrochemical immunoassay. A sandwich immunoreaction was performed on the immunochromatographic strip, and the captured QD labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable screen-printed electrode, which is embedded underneath the membrane on the test zone. The new device coupled with a portable electrochemical analyzer shows great promise for in-field and point-of-care quantitative testing of disease-related protein biomarkers. The parameters (e.g., voltammetric measurement of QD labels, antibody immobilization, the loading amount of QD-antibody, and the immunoreaction time) that govern the sensitivity and reproducibility of the device were optimized with IgG model analyte. The voltammetric response of the optimized device is highly linear over the range of 0.1-10 ng mL(-1) IgG, and the limit of detection is estimated to be 30 pg mL(-1) in association with a 7-min immunoreaction time. The detection limit was improved to 10 pg mL(-1) using a 20-min immunoreaction time. The device has been successfully applied for the detection of prostate-specific antigen (PSA) in human serum sample with a detection limit of 20 pg mL(-1). The results were validated by using the commercial PSA enzyme-linked immunosorbent assay kit and showed high consistency. The new disposable electrochemical diagnosis device thus provides a rapid, clinically accurate, and quantitative tool for protein biomarker detection.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17877418     DOI: 10.1021/ac070691i

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  24 in total

1.  Gold nanocage-based lateral flow immunoassay for immunoglobulin G.

Authors:  Yunhui Yang; Mehmet Ozsoz; Guodong Liu
Journal:  Mikrochim Acta       Date:  2017-03-31       Impact factor: 5.833

Review 2.  Towards a point-of-care test for active tuberculosis: obstacles and opportunities.

Authors:  Ruth McNerney; Peter Daley
Journal:  Nat Rev Microbiol       Date:  2011-03       Impact factor: 60.633

Review 3.  Diverse Applications of Nanomedicine.

Authors:  Beatriz Pelaz; Christoph Alexiou; Ramon A Alvarez-Puebla; Frauke Alves; Anne M Andrews; Sumaira Ashraf; Lajos P Balogh; Laura Ballerini; Alessandra Bestetti; Cornelia Brendel; Susanna Bosi; Monica Carril; Warren C W Chan; Chunying Chen; Xiaodong Chen; Xiaoyuan Chen; Zhen Cheng; Daxiang Cui; Jianzhong Du; Christian Dullin; Alberto Escudero; Neus Feliu; Mingyuan Gao; Michael George; Yury Gogotsi; Arnold Grünweller; Zhongwei Gu; Naomi J Halas; Norbert Hampp; Roland K Hartmann; Mark C Hersam; Patrick Hunziker; Ji Jian; Xingyu Jiang; Philipp Jungebluth; Pranav Kadhiresan; Kazunori Kataoka; Ali Khademhosseini; Jindřich Kopeček; Nicholas A Kotov; Harald F Krug; Dong Soo Lee; Claus-Michael Lehr; Kam W Leong; Xing-Jie Liang; Mei Ling Lim; Luis M Liz-Marzán; Xiaowei Ma; Paolo Macchiarini; Huan Meng; Helmuth Möhwald; Paul Mulvaney; Andre E Nel; Shuming Nie; Peter Nordlander; Teruo Okano; Jose Oliveira; Tai Hyun Park; Reginald M Penner; Maurizio Prato; Victor Puntes; Vincent M Rotello; Amila Samarakoon; Raymond E Schaak; Youqing Shen; Sebastian Sjöqvist; Andre G Skirtach; Mahmoud G Soliman; Molly M Stevens; Hsing-Wen Sung; Ben Zhong Tang; Rainer Tietze; Buddhisha N Udugama; J Scott VanEpps; Tanja Weil; Paul S Weiss; Itamar Willner; Yuzhou Wu; Lily Yang; Zhao Yue; Qian Zhang; Qiang Zhang; Xian-En Zhang; Yuliang Zhao; Xin Zhou; Wolfgang J Parak
Journal:  ACS Nano       Date:  2017-03-14       Impact factor: 15.881

Review 4.  Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments.

Authors:  Yan Huang; Tailin Xu; Wenqian Wang; Yongqiang Wen; Kun Li; Lisheng Qian; Xueji Zhang; Guodong Liu
Journal:  Mikrochim Acta       Date:  2019-12-18       Impact factor: 5.833

5.  Versailles Project on Advanced Materials and Standards Interlaboratory Study on Measuring the Thickness and Chemistry of Nanoparticle Coatings Using XPS and LEIS.

Authors:  Natalie A Belsey; David J H Cant; Caterina Minelli; Joyce R Araujo; Bernd Bock; Philipp Brüner; David G Castner; Giacomo Ceccone; Jonathan D P Counsell; Paul M Dietrich; Mark H Engelhard; Sarah Fearn; Carlos E Galhardo; Henryk Kalbe; Jeong Won Kim; Luis Lartundo-Rojas; Henry S Luftman; Tim S Nunney; Johannes Pseiner; Emily F Smith; Valentina Spampinato; Jacobus M Sturm; Andrew G Thomas; Jon P W Treacy; Lothar Veith; Michael Wagstaffe; Hai Wang; Meiling Wang; Yung-Chen Wang; Wolfgang Werner; Li Yang; Alexander G Shard
Journal:  J Phys Chem C Nanomater Interfaces       Date:  2016-09-13       Impact factor: 4.126

6.  Amperometric immunosensor for rapid detection of Mycobacterium tuberculosis.

Authors:  Morgan Hiraiwa; Jong-Hoon Kim; Hyun-Boo Lee; Shinnosuke Inoue; Annie L Becker; Kris M Weigel; Gerard A Cangelosi; Kyong-Hoon Lee; Jae-Hyun Chung
Journal:  J Micromech Microeng       Date:  2015       Impact factor: 1.881

7.  Development and evaluation of an immunochromatographic strip test based on the recombinant UL51 protein for detecting antibody against duck enteritis virus.

Authors:  Chanjuan Shen; Anchun Cheng; Mingshu Wang; Kunfeng Sun; Renyong Jia; Tao Sun; Na Zhang; Dekang Zhu; Qihui Luo; Yi Zhou; Xiaoyue Chen
Journal:  Virol J       Date:  2010-10-14       Impact factor: 4.099

8.  Nanoparticle-based electrochemical immunosensor for the detection of phosphorylated acetylcholinesterase: an exposure biomarker of organophosphate pesticides and nerve agents.

Authors:  Guodong Liu; Jun Wang; Richard Barry; Catherine Petersen; Charles Timchalk; Paul L Gassman; Yuehe Lin
Journal:  Chemistry       Date:  2008       Impact factor: 5.236

Review 9.  Nanotechnology-based electrochemical sensors for biomonitoring chemical exposures.

Authors:  Richard C Barry; Yuehe Lin; Jun Wang; Guodong Liu; Charles A Timchalk
Journal:  J Expo Sci Environ Epidemiol       Date:  2008-11-19       Impact factor: 5.563

10.  Simultaneous detection of nucleic acid and protein using gold nanoparticles and lateral flow device.

Authors:  Xun Mao; Anant Gurung; Hui Xu; Meenu Baloda; Yuqing He; Guodong Liu
Journal:  Anal Sci       Date:  2014       Impact factor: 2.081

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.