Detection and confirmation of staphylococcal enterotoxin B in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 fg/mL.

David Maraldo1, Raj Mutharasan.   

Abstract

A sensitive and reliable method for the detection of a model toxin, staphylococcal enterotoxin B (SEB) in buffer, apple juice, and milk is shown using piezoelectric-excited, millimeter-sized cantilever (PEMC) sensors. Limit of detection in spiked milk and apple juice samples is 10 and 100 fg, respectively. PEMC sensors (2 mm(2)) are prepared by immobilizing a polyclonal antibody specific to SEB, which was exposed to 1 mL of 1% milk and apple juice containing 10 fg-10 ng. Sensor response to 100 fg, 1 pg, and 10 pg of SEB in apple juice resulted in resonance frequency decreases of 113 +/- 18 (n = 4), 308 +/- 24 (n = 4), and 521 +/- 20 (n = 2) Hz, respectively. In milk, 10 fg, 100 fg, 1 pg, and 10 pg of SEB resulted in resonance frequency decreases of 126 +/- 18 (n = 2), 143 +/- 35 (n = 4), 310 +/- 32 (n = 5), and 557 +/- 25 (n = 2) Hz, respectively. Positive detection of SEB in the sample solution was observed within the first 20 min. The responses of the sensor to positive (SEB present, but no antibody on sensor), negative (SEB absent, antibody on sensor), and buffer (SEB absent, antibody on sensor) controls were -17 +/- 10 (n = 3), -9 +/- 5 (n = 3), and -6 +/- 12 (n = 18) Hz, respectively. Positive verification of SEB detection was confirmed by two methods: (1) low-pH buffer release caused increase in resonance frequency, and (2) second antibody binding to SEB attached to sensor that caused further resonance frequency decrease. The significance of these results is that PEMC sensors can reliably detect SEB at 10-100 fg (effective concentration of 2.5 and 25 fg/mL) in complex fluids without sample preparation or the use of labeled reagents.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17874846     DOI: 10.1021/ac070589l

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Photonic crystal lab-on-a-chip for detecting staphylococcal enterotoxin B at low attomolar concentration.

Authors:  Jin-Hee Han; Hee-Joo Kim; L Sudheendra; Shirley J Gee; Bruce D Hammock; Ian M Kennedy
Journal:  Anal Chem       Date:  2013-03-07       Impact factor: 6.986

2.  Carbon nanotubes with enhanced chemiluminescence immunoassay for CCD-based detection of Staphylococcal enterotoxin B in food.

Authors:  Minghui Yang; Yordan Kostov; Hugh A Bruck; Avraham Rasooly
Journal:  Anal Chem       Date:  2008-10-15       Impact factor: 6.986

3.  Optimizing two-color semiconductor nanocrystal immunoassays in single well microtiter plate formats.

Authors:  Kim E Sapsford; Samantha Spindel; Travis Jennings; Guoliang Tao; Robert C Triulzi; W Russ Algar; Igor L Medintz
Journal:  Sensors (Basel)       Date:  2011-08-11       Impact factor: 3.576

Review 4.  A Review of the Methods for Detection of Staphylococcus aureus Enterotoxins.

Authors:  Shijia Wu; Nuo Duan; Huajie Gu; Liling Hao; Hua Ye; Wenhui Gong; Zhouping Wang
Journal:  Toxins (Basel)       Date:  2016-06-24       Impact factor: 4.546

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.