| Literature DB >> 17873996 |
M J Mimica1, E N Berezin, R L B Carvalho, I M Mimica, L M J Mimica, M A P Sáfadi, E Schneider, H H Caiaffa-Filho.
Abstract
We evaluated the performance of several methods for the detection of methicillin resistance in Staphylococcus aureus using 101 clinical S. aureus isolates from pediatric patients in a tertiary hospital in Brazil; 50 isolates were mecA-positive and 51 were mecA-negative. The Etest and oxacillin agar screening plates were 100% sensitive and specific for mecA presence. Oxacillin and cefoxitin disks gave sensitivities of 96 and 92%, respectively, and 98% specificity. Alterations of CLSI cefoxitin breakpoints increased sensitivity to 98%, without decreasing specificity. Our results highlight the importance of a continuing evaluation of the recommended microbiological methods by different laboratories and in different settings. If necessary, laboratories should use a second test before reporting a strain as susceptible, especially when testing strains isolated from invasive or serious infections. With the new (2007) CLSI breakpoints, the cefoxitin-disk test appears to be a good option for the detection of methicillin resistance in S. aureus.Entities:
Mesh:
Substances:
Year: 2007 PMID: 17873996 DOI: 10.1590/s1413-86702007000400009