Diametral tensile strength of dual-curing resin cements submitted exclusively to autopolymerization.

Renata Garcia Fonseca1, Thais Paci Artusi, Juliana Gomes dos Santos, Gelson Luis Adabo.   

Abstract

OBJECTIVES: To evaluate, at different times, the diametral tensile strength (DTS) of dual-curing resin cements that were not photopolymerized. METHOD AND MATERIALS: Equal amounts of base and catalyst pastes of Panavia F (Kuraray), Variolink II (Vivadent), Rely X (3M ESPE), and Enforce (Dentsply) were mixed and inserted into cylindrical molds (4 x 2 mm) (n = 10). Cements were not photopolymerized. DTS test was performed in a testing machine at 30 minutes, 1 hour, 24 hours, and 7 days. The specimens were stored in light-proof containers with distilled water at 37 degrees C until the time of assay. An autopolymerizing resin cement (Cement-It, Jeneric Pentron) and a zinc phosphate cement served as controls. One-way analysis of variance (ANOVA) and Tukey test were performed separately for each cement and for each time (P <.05).
RESULTS: All cements showed an increase in DTS when tested at 1 and 24 hours. Tests at 24 hours and 7 days revealed no statistically significant differences. In all groups, the zinc phosphate cement had the lowest DTS mean values (2.1 MPa, 3.6 MPa, 6.5 MPa, and 6.9 MPa), while Cement-It (35.1 MPa, 33.6 MPa, 46.9 MPa, and 46.3 MPa) and Enforce (31.9 MPa, 31.7 MPa, 43.4 MPa, and 47.6 MPa) presented the highest DTS mean values.
CONCLUSION: All cements presented maximal strength at 24 hours. The dual-curing resin cements, even when nonphotopolymerized, demonstrated higher DTS than the zinc phosphate cement and similar or lower values than the autopolymerizing resin cement.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17873972

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  5 in total

1.  The effect of variability in the powder/liquid ratio on the strength of zinc phosphate cement.

Authors:  Jill E McKenna; Noel J Ray; Gerald McKenna; Francis M Burke
Journal:  Int J Dent       Date:  2011-12-08

2.  Diametral tensile strength and film thickness of an experimental dental luting agent derived from castor oil.

Authors:  Juliana Cabrini Carmello; Laiza Maria Grassi Fais; Lígia Nunes de Moraes Ribeiro; Salvador Claro Neto; Dalton Geraldo Guaglianoni; Lígia Antunes Pereira Pinelli
Journal:  J Appl Oral Sci       Date:  2012-02       Impact factor: 2.698

3.  Effect of aging and curing mode on the compressive and indirect tensile strength of resin composite cements.

Authors:  Nadja Rohr; Jens Fischer
Journal:  Head Face Med       Date:  2017-11-21       Impact factor: 2.151

4.  HF etching of CAD/CAM materials: influence of HF concentration and etching time on shear bond strength.

Authors:  Antonio Straface; Lena Rupp; Aiste Gintaute; Jens Fischer; Nicola U Zitzmann; Nadja Rohr
Journal:  Head Face Med       Date:  2019-08-08       Impact factor: 2.151

5.  A comprehensive in vitro study on the performance of two different strategies to simplify adhesive bonding.

Authors:  Nadja Rohr; Sabrina Märtin; Nicola U Zitzmann; Jens Fischer
Journal:  J Esthet Restor Dent       Date:  2022-03-19       Impact factor: 3.040

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.