Literature DB >> 17873764

Variability of the analysis of the tear meniscus height by optical coherence tomography.

Etty Bitton1, Adam Keech, Trefford Simpson, Lyndon Jones.   

Abstract

PURPOSE: Tear meniscus height (TMH) is an established parameter indicative of tear film volume and has recently been determined using an optical coherence tomographer (OCT). The purpose of this study was to evaluate the inter and intra observer variability in TMH assessment using OCT.
METHODS: Ten subjects (6 M, 4 F; aged 32.5 +/- 6.4 years) had 10 consecutive scans taken of their inferior central tear meniscus (5 scans originating at 90 degrees and 5 origination at 270 degrees) using the OCT2 (Humphrey-Zeiss). Images were analyzed by two observers using custom software on three separate occasions. Following a training session among observers, the images were reevaluated to assess differences in variability. Data were analyzed for differences within and across examiners, for the effect of examiner training and between scan directions.
RESULTS: The mean TMH and tear volume collapsed across subjects were between 0.24 and 0.25 mm and 25 to 27 nL/mm, respectively. No difference was noted within observers. An interobserver mean volume difference (p = 0.044) was present but was eliminated post training (p = 0.167). Variability was less with scans originating at 90 degrees.
CONCLUSIONS: The values of the TMH and tear volume are similar to those reported in the literature. Due to the interobserver differences observed, a training session between examiners may prove to be valuable, especially in a large or multicenter study.

Entities:  

Mesh:

Year:  2007        PMID: 17873764     DOI: 10.1097/OPX.0b013e3181560ba8

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  9 in total

1.  Is optical coherence tomography an effective device for evaluation of tear film meniscus in patients with acne rosacea?

Authors:  F C Eroglu; A Karalezli; R Dursun
Journal:  Eye (Lond)       Date:  2016-01-15       Impact factor: 3.775

2.  Correlation between optical coherence tomography-derived assessments of lower tear meniscus parameters and clinical features of dry eye disease.

Authors:  Pho Nguyen; David Huang; Yan Li; Srinivas R Sadda; Sylvia Ramos; Rajeev R Pappuru; Samuel C Yiu
Journal:  Cornea       Date:  2012-06       Impact factor: 2.651

3.  Neurostimulation of the lacrimal nerve for enhanced tear production.

Authors:  Andrea L Kossler; Jianhua Wang; William Feuer; David T Tse
Journal:  Ophthalmic Plast Reconstr Surg       Date:  2015 Mar-Apr       Impact factor: 1.746

4.  Effect of topical steroids on recently developed incomplete nasolacrimal duct obstruction: optical coherence tomography study.

Authors:  Min Kyu Yang; Namju Kim; Ho-Kyung Choung; Sang In Khwarg
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-07-24       Impact factor: 3.117

Review 5.  Ultra high-resolution anterior segment optical coherence tomography in the diagnosis and management of ocular surface squamous neoplasia.

Authors:  Benjamin J Thomas; Anat Galor; Afshan A Nanji; Fouad El Sayyad; Jianhua Wang; Sander R Dubovy; Madhura G Joag; Carol L Karp
Journal:  Ocul Surf       Date:  2013-11-09       Impact factor: 5.033

6.  Automatic dynamic tear meniscus measurement in optical coherence tomography.

Authors:  Maciej M Bartuzel; Dorota H Szczesna-Iskander; D Robert Iskander
Journal:  Biomed Opt Express       Date:  2014-07-23       Impact factor: 3.732

7.  Changes in Tear Meniscus Height Following Lower Blepharoplasty as Measured by Optical Coherence Tomography.

Authors:  Sang Min Lee; Sok Joong Chung; Jong Seo Park; Helen Lew
Journal:  Korean J Ophthalmol       Date:  2018-10

8.  Bony nasolacrimal duct size and outcomes of nasolacrimal silicone intubation for incomplete primary acquired nasolacrimal duct obstruction.

Authors:  Min Kyu Yang; Ho-Seok Sa; Namju Kim; Jeong Hun Kim; Hokyung Choung; Sang In Khwarg
Journal:  PLoS One       Date:  2022-03-28       Impact factor: 3.240

9.  Changes in ocular surface after withdrawal of anti-glaucoma medications following non-penetrating deep sclerectomy.

Authors:  Carlota Fuente-García; Francisco José Muñoz-Negrete; Elisabet de Dompablo; Javier Moreno-Montañés; Gema Rebolleda
Journal:  Indian J Ophthalmol       Date:  2022-05       Impact factor: 2.969

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.