Literature DB >> 17867799

Corneal birefringence compensation for polarization sensitive optical coherence tomography of the human retina.

Michael Pircher1, Erich Götzinger, Bernhard Baumann, Christoph K Hitzenberger.   

Abstract

In previous publications we have reported on polarization-sensitive optical coherence tomography (PS-OCT) systems that measure and image retardation and axis orientation of birefringent samples with only a single input polarization state. This method requires that the sample is illuminated by circularly polarized light. In the case of retinal imaging, the retina is measured through the birefringent cornea, which causes a deviation of the sampling beam from the circular polarization state. To obtain undistorted birefringence patterns of the retina by PS-OCT, the corneal birefringence has to be compensated. We report on a software-based corneal birefringence compensation that uses the polarization state of the light backscattered at the retinal surface to measure the corneal birefringence. This information is used to numerically compensate the corneal birefringence. Contrary to hardware-based solutions, our method accounts for local variations of the corneal birefringence. We implemented the method in a state of the art spectral domain PS-OCT system and demonstrate it in a test sample and human retina in vivo.

Entities:  

Mesh:

Year:  2007        PMID: 17867799     DOI: 10.1117/1.2771560

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  26 in total

1.  Henle fiber layer phase retardation measured with polarization-sensitive optical coherence tomography.

Authors:  Barry Cense; Qiang Wang; Sangyeol Lee; Liang Zhao; Ann E Elsner; Christoph K Hitzenberger; Donald T Miller
Journal:  Biomed Opt Express       Date:  2013-10-01       Impact factor: 3.732

Review 2.  Optical coherence tomography: history, current status, and laboratory work.

Authors:  Michelle L Gabriele; Gadi Wollstein; Hiroshi Ishikawa; Larry Kagemann; Juan Xu; Lindsey S Folio; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-14       Impact factor: 4.799

3.  Retinal nerve fiber bundle tracing and analysis in human eye by polarization sensitive OCT.

Authors:  Mitsuro Sugita; Michael Pircher; Stefan Zotter; Bernhard Baumann; Philipp Roberts; Tomoyuki Makihira; Nobuhiro Tomatsu; Makoto Sato; Clemens Vass; Christoph K Hitzenberger
Journal:  Biomed Opt Express       Date:  2015-02-26       Impact factor: 3.732

4.  Motion artifact and speckle noise reduction in polarization sensitive optical coherence tomography by retinal tracking.

Authors:  Mitsuro Sugita; Stefan Zotter; Michael Pircher; Tomoyuki Makihira; Kenichi Saito; Nobuhiro Tomatsu; Makoto Sato; Philipp Roberts; Ursula Schmidt-Erfurth; Christoph K Hitzenberger
Journal:  Biomed Opt Express       Date:  2013-12-06       Impact factor: 3.732

5.  Vectorial birefringence imaging by optical coherence microscopy for assessing fibrillar microstructures in the cornea and limbus.

Authors:  Qingyun Li; Karol Karnowski; Gavrielle Untracht; Peter B Noble; Barry Cense; Martin Villiger; David D Sampson
Journal:  Biomed Opt Express       Date:  2020-01-24       Impact factor: 3.732

6.  Polarization maintaining fiber based ultra-high resolution spectral domain polarization sensitive optical coherence tomography.

Authors:  Erich Götzinger; Bernhard Baumann; Michael Pircher; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2009-12-07       Impact factor: 3.894

7.  Polarization properties of single layers in the posterior eyes of mice and rats investigated using high resolution polarization sensitive optical coherence tomography.

Authors:  Stanislava Fialová; Marco Augustin; Martin Glösmann; Tanja Himmel; Sabine Rauscher; Marion Gröger; Michael Pircher; Christoph K Hitzenberger; Bernhard Baumann
Journal:  Biomed Opt Express       Date:  2016-03-24       Impact factor: 3.732

8.  Mueller matrix retinal imager with optimized polarization conditions.

Authors:  K M Twietmeyer; R A Chipman; A E Elsner; Y Zhao; D VanNasdale
Journal:  Opt Express       Date:  2008-12-22       Impact factor: 3.894

9.  Fiber-optic catheter-based polarization-sensitive OCT for radio-frequency ablation monitoring.

Authors:  Xiaoyong Fu; Zhao Wang; Hui Wang; Yves T Wang; Michael W Jenkins; Andrew M Rollins
Journal:  Opt Lett       Date:  2014-09-01       Impact factor: 3.776

10.  Analysis of the origin of atypical scanning laser polarimetry patterns by polarization-sensitive optical coherence tomography.

Authors:  Erich Götzinger; Michael Pircher; Bernhard Baumann; Cornelia Hirn; Clemens Vass; Christoph K Hitzenberger
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-12       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.