High frequency of unrecognized hypoglycaemias in patients with Type 2 diabetes is discovered by continuous glucose monitoring.

K K Weber1, T Lohmann, K Busch, I Donati-Hirsch, R Riel.   

Abstract

AIMS: To evaluate the use of a CGMS in the detection of hypoglycaemia in people with type 2 diabetes as an outpatient procedure.
METHODS: 31 type 2 diabetic patients underwent glucose monitoring by means of CGMS (Medtronic MiniMed) for up to three days. Patients took part in at least four SMBG (self monitoring blood glucose) tests per day. After three days of monitoring, the CGMS data was downloaded and analysed by a physician to identify the frequency of hypoglycaemias (< or =50 mg/dl) and borderline values (51-70 mg/dl), their duration and distribution. Findings were discussed with the patient and if necessary treatment was adjusted. Eight weeks later, monitoring was repeated to asses the effects of the adjusted treatment.
RESULTS: Average duration of sensor wear was 4.19 days. Correlation between the sensor and the SMBG readings was high. A high number of hypoglycaemias and borderline values were detected by the CGMS, most of them unrecognized by the patient. The frequency of hypoglycaemias and borderline values just as the duration could be significantly reduced from first to second monitoring.
CONCLUSION: Using the CGMS in type 2 diabetic patients achieved the detection of numerous hypoglycaemias and borderline values both nocturnal and/or unnoticed. The CGMS provides accurate data, which cannot be achieved by conventional SMBG tests. That opens the possibility for treatment adjustment and improvement in metabolic control. For patients it provides a better understanding of the effects of insulin or oral agents, nutrition and exercises to their glucose level.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17853331     DOI: 10.1055/s-2007-984452

Source DB:  PubMed          Journal:  Exp Clin Endocrinol Diabetes        ISSN: 0947-7349            Impact factor:   2.949


  19 in total

1.  Professional continuous glucose monitoring in subjects with type 1 diabetes: retrospective hypoglycemia detection.

Authors:  Morten Hasselstrøm Jensen; Toke Folke Christensen; Lise Tarnow; Zeinab Mahmoudi; Mette Dencker Johansen; Ole Kristian Hejlesen
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

2.  Clinical Use of Professional Continuous Glucose Monitoring.

Authors:  Eugene E Wright; James R Gavin
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

3.  The Changing Landscape of Glycemic Targets: Focus on Continuous Glucose Monitoring.

Authors:  Pamela R Kushner; Davida F Kruger
Journal:  Clin Diabetes       Date:  2020-10

4.  A Multicenter Evaluation of the Performance and Usability of a Novel Glucose Monitoring System in Chinese Adults With Diabetes.

Authors:  Linong Ji; Xiaohui Guo; Lixin Guo; Qian Ren; Nan Yu; Jie Zhang
Journal:  J Diabetes Sci Technol       Date:  2016-09-25

5.  Recurrent Hypoglycemia Exacerbates Cerebral Ischemic Damage in Diabetic Rats via Enhanced Post-Ischemic Mitochondrial Dysfunction.

Authors:  Vibha Shukla; Perry Fuchs; Allen Liu; Charles H Cohan; Chuanhui Dong; Clinton B Wright; Miguel A Perez-Pinzon; Kunjan R Dave
Journal:  Transl Stroke Res       Date:  2018-03-22       Impact factor: 6.829

6.  Hypoglycemia in Type 2 Diabetes--More Common Than You Think: A Continuous Glucose Monitoring Study.

Authors:  Richa Redhu Gehlaut; Godwin Y Dogbey; Frank L Schwartz; Cynthia R Marling; Jay H Shubrook
Journal:  J Diabetes Sci Technol       Date:  2015-04-27

7.  Adjuvant Liraglutide and Insulin Versus Insulin Monotherapy in the Closed-Loop System in Type 1 Diabetes: A Randomized Open-Labeled Crossover Design Trial.

Authors:  Jeniece Trast Ilkowitz; Ranjitha Katikaneni; Martin Cantwell; Neesha Ramchandani; Rubina A Heptulla
Journal:  J Diabetes Sci Technol       Date:  2016-08-22

8.  Feasibility and acceptability of continuous glucose monitoring and accelerometer technology in exercising individuals with type 2 diabetes.

Authors:  Nancy A Allen; Cynthia S Jacelon; Stuart R Chipkin
Journal:  J Clin Nurs       Date:  2009-02       Impact factor: 3.036

9.  Continuous Glucose Monitoring for the Detection of Hypoglycemia in Patients With Diabetes of the Exocrine Pancreas.

Authors:  Channabasappa Shivaprasad; Kolla Gautham; Kejal Shah; Soumya Gupta; Preethika Palani; Biswas Anupam
Journal:  J Diabetes Sci Technol       Date:  2020-12-16

10.  Gender difference in response predictors after 1-year exenatide therapy twice daily in type 2 diabetic patients: a real world experience.

Authors:  Roberto Anichini; Sabrina Cosimi; Alberto Di Carlo; Paola Orsini; Alessandra De Bellis; Giuseppe Seghieri; Flavia Franconi; Fabio Baccetti
Journal:  Diabetes Metab Syndr Obes       Date:  2013-04-08       Impact factor: 3.168

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.