Literature DB >> 1785234

Effects of pleural fluid and positive end-expiratory pressure on the measurement of extravascular lung water by the double-indicator dilution technique.

H Blomqvist1, C J Wickerts, P G Rösblad.   

Abstract

The reliability of the double-indicator dilution technique (dye/cold) for measuring extravascular lung water (EVLW) has been studied in lung-healthy dogs after pleural fluid injection of saline (up to 20 ml/kg) during mechanical ventilation at zero and 10 cmH2O (1.0 kPa) end-expiratory pressure (ZEEP and PEEP, respectively). Pleural fluid injection had no effect on EVLW at either ZEEP or PEEP. PEEP induced changes in cardiac output, and reduced both the intravascular (dye) and the thermal indicator volumes, but with no effect on the calculated EVLW. It is concluded that pleural fluid up to 20 ml/kg and ventilation with PEEP of 10 cmH2O (1.0 kPa) do not affect the reliability of the double-indicator dilution technique for measuring extravascular lung water in the dog.

Entities:  

Mesh:

Year:  1991        PMID: 1785234     DOI: 10.1111/j.1399-6576.1991.tb03352.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  5 in total

1.  Comparison of gravimetric and a double-indicator dilution technique for assessment of extra-vascular lung water in endotoxaemia.

Authors:  P Rossi; A Oldner; M Wanecek; L G Leksell; A Rudehill; D Konrad; E Weitzberg
Journal:  Intensive Care Med       Date:  2003-02-08       Impact factor: 17.440

2.  The clinical usefulness of extravascular lung water and pulmonary vascular permeability index to diagnose and characterize pulmonary edema: a prospective multicenter study on the quantitative differential diagnostic definition for acute lung injury/acute respiratory distress syndrome.

Authors:  Shigeki Kushimoto; Yasuhiko Taira; Yasuhide Kitazawa; Kazuo Okuchi; Teruo Sakamoto; Hiroyasu Ishikura; Tomoyuki Endo; Satoshi Yamanouchi; Takashi Tagami; Junko Yamaguchi; Kazuhide Yoshikawa; Manabu Sugita; Yoichi Kase; Takashi Kanemura; Hiroyuki Takahashi; Yuichi Kuroki; Hiroo Izumino; Hiroshi Rinka; Ryutarou Seo; Makoto Takatori; Tadashi Kaneko; Toshiaki Nakamura; Takayuki Irahara; Nobuyuki Saito; Akihiro Watanabe
Journal:  Crit Care       Date:  2012-12-11       Impact factor: 9.097

3.  Validation of extravascular lung water measurement by single transpulmonary thermodilution: human autopsy study.

Authors:  Takashi Tagami; Shigeki Kushimoto; Yasuhiro Yamamoto; Takahiro Atsumi; Ryoichi Tosa; Kiyoshi Matsuda; Renpei Oyama; Takanori Kawaguchi; Tomohiko Masuno; Hisao Hirama; Hiroyuki Yokota
Journal:  Crit Care       Date:  2010-09-06       Impact factor: 9.097

4.  Extravascular lung water in critical care: recent advances and clinical applications.

Authors:  Mathieu Jozwiak; Jean-Louis Teboul; Xavier Monnet
Journal:  Ann Intensive Care       Date:  2015-11-06       Impact factor: 6.925

5.  Comparison of quantitative computed tomography analysis and single-indicator thermodilution to measure pulmonary edema in patients with acute respiratory distress syndrome.

Authors:  Fan Zhang; Chen Li; Jian-ning Zhang; Hai-peng Guo; Da-wei Wu
Journal:  Biomed Eng Online       Date:  2014-03-13       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.