Literature DB >> 17846712

Optimization and safety of the intra-aortic balloon pumping balloon catheter.

Nobumasa Tsutsui1, Yoko Tsutsui, Yasuhiro Tsutsui, Kazuaki Hashimoto, Kyoko Miwa, Kazuhide Kato.   

Abstract

Tokai Medical Products developed an intra-aortic balloon pumping (IABP) balloon catheter with the following unique characteristics: the balloon can be applied to any patient irrespective of their physical size, and is therefore suitable for Japanese patients of small stature; a long soft tip is used, which is designed to avoid damage to blood vessels; the size of the catheter is reduced to 7 Fr, and the catheter can be used as a multifunctional balloon catheter, such as the Yoshioka type, that allows simultaneous percutaneous coronary intervention (PCI). The safety of this catheter has been proven in scientific studies. In this review, we report the development of our IABP balloon catheter and give an outline of its characteristics.

Entities:  

Mesh:

Year:  2007        PMID: 17846712     DOI: 10.1007/s10047-007-0385-0

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  13 in total

1.  [The method of fixation of intra-aortic balloon catheter in the iliac artery without sheath introducer].

Authors:  Y Yoshioka; N Tsutsui
Journal:  Kyobu Geka       Date:  1990-08

2.  Assisted circulation. I. The arterial counterpulsator.

Authors:  R H CLAUSS; W C BIRTWELL; G ALBERTAL; S LUNZER; W J TAYLOR; A M FOSBERG; D E HARKEN
Journal:  J Thorac Cardiovasc Surg       Date:  1961-04       Impact factor: 5.209

3.  Experimental augmentation of coronary flow by retardation of the arterial pressure pulse.

Authors:  A KANTROWITZ
Journal:  Surgery       Date:  1953-10       Impact factor: 3.982

4.  Intraaortic balloon pump insertion through the subclavian artery. Subclavian artery insertion of IABP.

Authors:  Constantin B Marcu; Thomas J Donohue; Antoine Ferneini; Andre E Ghantous
Journal:  Heart Lung Circ       Date:  2005-10-20       Impact factor: 2.975

5.  Diastolic balloon pumping (with carbon dioxide) in the aorta--a mechanical assistance to the failing circulation.

Authors:  S D MOULOPOULOS; S TOPAZ; W J KOLFF
Journal:  Am Heart J       Date:  1962-05       Impact factor: 4.749

6.  [Intra-aortic balloon pumping (IABP) in serious heart failure following open heart surgery in an infant].

Authors:  M Ohmi; S Furukawa; F Mori; S Kurata; K Esato; T Mouri; H Kaneko
Journal:  Kyobu Geka       Date:  1983-01

7.  A clinical experience with an implanted mechanical auxiliary ventricle.

Authors:  A Kantrowitz; T Akutsu; P A Chaptal; J Krakauer; A R Kantrowitz; R T Jones
Journal:  JAMA       Date:  1966-08-15       Impact factor: 56.272

8.  Contemporary utilization and outcomes of intra-aortic balloon counterpulsation in acute myocardial infarction: the benchmark registry.

Authors:  Gregg W Stone; E Magnus Ohman; Michael F Miller; Debra L Joseph; Jan T Christenson; Marc Cohen; Philip M Urban; Ramachandra C Reddy; Robert J Freedman; Karen L Staman; James J Ferguson
Journal:  J Am Coll Cardiol       Date:  2003-06-04       Impact factor: 24.094

9.  Vascular complications of intra-aortic balloon insertion in patients undergoing coronary reavscularization: analysis of 911 cases.

Authors:  Zile Singh Meharwal; Naresh Trehan
Journal:  Eur J Cardiothorac Surg       Date:  2002-04       Impact factor: 4.191

10.  Modification of intraaortic balloon catheter to permit introduction by cardiac catheterization techniques.

Authors:  S Wolfson; D L Karsh; R A Langou; A S Geha; G L Hammond; L S Cohen
Journal:  Am J Cardiol       Date:  1978-04       Impact factor: 2.778

View more
  1 in total

Review 1.  Journal of Artificial Organs 2007: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; M Nishimura; T Nishimura; Y Tomizawa; T Yamaoka; H Watanabe
Journal:  J Artif Organs       Date:  2008-04-15       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.