Influence of length and diameter of implants associated with distal extension removable partial dentures.

Fellippo Ramos Verri1, Eduardo Piza Pellizzer, Eduardo Passos Rocha, João Antônio Pereira.   

Abstract

PURPOSE: The aim of this study was to evaluate the influence of the length and diameter of the implant incorporated under the saddle of a distal-extension removable partial denture, acting as support.
MATERIALS AND METHODS: Six hemi-mandibular models were made with the presence of left inferior cuspid and first bicuspid, with the following differences: model A, without removable partial denture; model B, removable partial denture only; model C, removable partial denture and implant of 3.75 x x mm; model D, removable partial denture and implant of 3.75 x x3 mm; model E, removable partial denture and implant of 5 x x mm; and model F, removable partial denture and implant of 5 x x3 mm. These models were designed with the aid of AutoCAD 2000 (Autodesk, Inc., San Rafael, CA) and processed for finite element analysis by ANSYS 5.4 (Swanson Analysis Systems, Houston, PA). The loads applied were 50 N vertical on each cuspid point.
RESULTS: It was noted that the presence of the removable partial denture overloaded the supporting tooth and other structures. The introduction of the implant reduced tensions, mainly at the extremities of the edentulous edge. Both the length and diameter tended to reduce tensions as their dimensions increased.
CONCLUSIONS: Increasing the length of the implant had a great influence on the decrease of displacement and von Mises tension values. Increasing the diameter of the implant had a great influence on the decrease of von Mises tension values, but did not influence the displacement values. According to the results of this study, it is a good choice to use the greater and larger implant possible in the association between implant and distal extension removable partial denture.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17846543     DOI: 10.1097/ID.0b013e31805007aa

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  7 in total

1.  Influence of Implant Position on Stress Distribution in Implant-Assisted Distal Extension Removable Partial Dentures: A 3D Finite Element Analysis.

Authors:  Yeganeh Memari; Allahyar Geramy; Amir Fayaz; Shirin Rezvani Habib Abadi; Yasaman Mansouri
Journal:  J Dent (Tehran)       Date:  2014-09-30

2.  Distal extension mandibular removable partial denture with implant support.

Authors:  Canan Bural; Begum Buzbas; Sebnem Ozatik; Gulsen Bayraktar; Yusuf Emes
Journal:  Eur J Dent       Date:  2016 Oct-Dec

3.  Mechanical behavior of implant assisted removable partial denture for Kennedy class II.

Authors:  João-Paulo-Mendes Tribst; Rodrigo-Máximo de Araújo; Naiara-Pires Ramanzine; Natália-Ribeiro Santos; Amanda-Maria-de Oliveira Dal Piva; Alexandre-Luiz-Souto Borges; João-Mauricio-Ferraz da Silva
Journal:  J Clin Exp Dent       Date:  2020-01-01

4.  Effect of the Location of Dental Mini-Implants on Strain Distribution under Mandibular Kennedy Class I Implant-Retained Removable Partial Dentures.

Authors:  Pimduen Rungsiyakull; Kallaya Kujarearntaworn; Pathawee Khongkhunthian; Michael Swain; Chaiy Rungsiyakull
Journal:  Int J Dent       Date:  2021-05-04

5.  Strain Distribution in a Kennedy Class I Implant Assisted Removable Partial Denture under Various Loading Conditions.

Authors:  Reza Shahmiri; John M Aarts; Vincent Bennani; Raj Das; Michael V Swain
Journal:  Int J Dent       Date:  2013-04-30

Review 6.  Biomechanics of oral mucosa.

Authors:  Junning Chen; Rohana Ahmad; Wei Li; Michael Swain; Qing Li
Journal:  J R Soc Interface       Date:  2015-08-06       Impact factor: 4.118

7.  Effects of Length and Inclination of Implants on Terminal Abutment Teeth and Implants in Mandibular CL1 Removable Partial Denture Assessed by Three-Dimensional Finite Element Analysis.

Authors:  Amir Fayaz; Alahyar Geramy; Yeganeh Memari; Zahra Rahmani
Journal:  J Dent (Tehran)       Date:  2015-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.