Entrapped air and its effects on dye penetration of voids.

C M Oliver1, P V Abbott.   

Abstract

This study was conducted to determine the effect of entrapped air on the ability of methylene blue dye to penetrate known and measurable voids. Thirty six capillary tubes were sealed at one end and had standardized voids created within the lumen. Three equal groups of 12 test specimens and 4 controls were subjected to dye penetration by the methods of passive immersion for 7 days, centrifuging at 3,000 rpm for 5 minutes and immersion in a vacuum of 26 mm of mercury for 5 minutes. Measurement of linear dye penetration was made by removing shavings from the sealed end until dye could be observed. Negative controls showed no dye penetration and positive controls showed complete penetration. The vacuum method showed 100% penetration in all cases, while centrifuging had a mean of 91.7 /+ 8.7% penetration and passive immersion had a mean of 20.7 +/- 5.4% penetration. This study demonstrates that passive dye leakage studies are unreliable and very variable. The vacuum method whereby all entrapped air is removed is the most reliable method for dye penetration studies.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1782904     DOI: 10.1111/j.1600-9657.1991.tb00198.x

Source DB:  PubMed          Journal:  Endod Dent Traumatol        ISSN: 0109-2502


  6 in total

1.  En face optical coherence tomography investigation of apical microleakage after laser-assisted endodontic treatment.

Authors:  Carmen Todea; Cosmin Balabuc; Cosmin Sinescu; Laura Filip; Cristina Kerezsi; Mircea Calniceanu; Meda Negrutiu; Adrian Bradu; Michael Hughes; Adrian Gh Podoleanu
Journal:  Lasers Med Sci       Date:  2009-05-20       Impact factor: 3.161

2.  Assessment of different dyes used in leakage studies.

Authors:  Johannes Mente; Stephan Ferk; Jens Dreyhaupt; Andreas Deckert; Milos Legner; Hans Joerg Staehle
Journal:  Clin Oral Investig       Date:  2009-06-18       Impact factor: 3.573

3.  Sodium hypochlorite penetration into dentinal tubules after manual dynamic agitation and ultrasonic activation: a histochemical evaluation.

Authors:  Luigi Generali; Erica Campolongo; Ugo Consolo; Carlo Bertoldi; Luciano Giardino; Francesco Cavani
Journal:  Odontology       Date:  2018-03-28       Impact factor: 2.634

4.  Microleakage of flowable composite restorations.

Authors:  Vasudev Ballal
Journal:  Eur J Dent       Date:  2010-07

5.  A comparative evaluation of dentinal hypersensitivity and microleakage associated with composite restorations in cavities preconditioned with air abrasion - An ex vivo study.

Authors:  Ankit Arora; Shashi Rashmi Acharya; Saraswathi M Vidya; Padmaja Sharma
Journal:  Contemp Clin Dent       Date:  2012-07

6.  Letter to the Editor.

Authors:  SaravanaKarthikeyan Balasubramanian; Nidambur Vasudev Ballal
Journal:  Iran Endod J       Date:  2017
  6 in total