Literature DB >> 17827051

Image filtering via generalized scale.

Andre Souza1, Jayaram K Udupa, Anant Madabhushi.   

Abstract

In medical imaging, low signal-to-noise ratio (SNR) and/or contrast-to-noise ratio (CNR) often cause many image processing algorithms to perform poorly. Postacquisition image filtering is an important off-line image processing approach widely employed to enhance the SNR and CNR. A major drawback of many filtering techniques is image degradation by diffusing/blurring edges and/or fine structures. In this paper, we introduce a scale-based filtering method that employs scale-dependent diffusion conductance to perform filtering. This approach utilizes novel object scale information via a concept called generalized scale, which imposes no shape, size, or anisotropic constraints unlike previously published ball scale-based filtering strategies. The object scale allows us to better control the filtering process by constraining smoothing in regions with fine details and in the vicinity of boundaries while permitting effective smoothing in the interior of homogeneous regions. A new quantitative evaluation strategy that captures the SNR to CNR trade-off behavior of filtering methods is presented. The evaluations based on the Brainweb data sets show superior performance of generalized scale-based diffusive filtering over two existing methods, namely, ball scale-based and nonlinear complex diffusion processes. Qualitative experiments based on both phantom and patient magnetic resonance images demonstrate that the generalized scale-based approach leads to better preservation of fine details and edges.

Entities:  

Mesh:

Year:  2007        PMID: 17827051      PMCID: PMC2478642          DOI: 10.1016/j.media.2007.07.007

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  19 in total

1.  Anisotropic diffusion filtering of PET attenuation data to improve emission images.

Authors:  Omer Demirkaya
Journal:  Phys Med Biol       Date:  2002-10-21       Impact factor: 3.609

2.  Flux-based anisotropic diffusion applied to enhancement of 3-D angiogram.

Authors:  Karl Krissian
Journal:  IEEE Trans Med Imaging       Date:  2002-11       Impact factor: 10.048

3.  Noise reduction for magnetic resonance images via adaptive multiscale products thresholding.

Authors:  Paul Bao; Lei Zhang
Journal:  IEEE Trans Med Imaging       Date:  2003-09       Impact factor: 10.048

4.  Diffusion-enhanced visualization and quantification of vascular anomalies in three-dimensional rotational angiography: results of an in-vitro evaluation.

Authors:  Erik Meijering; Wiro Niessen; Joachim Weickert; Max Viergever
Journal:  Med Image Anal       Date:  2002-09       Impact factor: 8.545

5.  Vector-valued image regularization with PDEs: a common framework for different applications.

Authors:  D Tschumperle; R Deriche
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2005-04       Impact factor: 6.226

6.  The digital TV filter and nonlinear denoising.

Authors:  T F Chan; S Osher; J Shen
Journal:  IEEE Trans Image Process       Date:  2001       Impact factor: 10.856

7.  Fractal image denoising.

Authors:  Mohsen Ghazel; George H Freeman; Edward R Vrscay
Journal:  IEEE Trans Image Process       Date:  2003       Impact factor: 10.856

8.  Nonlinear anisotropic filtering of MRI data.

Authors:  G Gerig; O Kubler; R Kikinis; F A Jolesz
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

9.  Selection of task-dependent diffusion filters for the post-processing of SPECT images.

Authors:  F J Beekman; E T Slijpen; W J Niessen
Journal:  Phys Med Biol       Date:  1998-06       Impact factor: 3.609

10.  Multi-modal volume registration by maximization of mutual information.

Authors:  W M Wells; P Viola; H Atsumi; S Nakajima; R Kikinis
Journal:  Med Image Anal       Date:  1996-03       Impact factor: 8.545

View more
  3 in total

1.  Tensor scale: An analytic approach with efficient computation and applications.

Authors:  Ziyue Xu; Punam K Saha; Soura Dasgupta
Journal:  Comput Vis Image Underst       Date:  2012-10-01       Impact factor: 3.876

2.  Spectral embedding based active contour (SEAC) for lesion segmentation on breast dynamic contrast enhanced magnetic resonance imaging.

Authors:  Shannon C Agner; Jun Xu; Anant Madabhushi
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

3.  Application of off-line image processing for optimization in chest computed radiography using a low cost system.

Authors:  Wilbroad E Muhogora; Peter Msaki; Renato Padovani
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.