Literature DB >> 17826936

Assessment of left ventricular function with 16- and 64-slice multi-detector computed tomography.

Suhny Abbara1, Benjamin J W Chow, Antonio J Pena, Ricardo C Cury, Udo Hoffmann, Koen Nieman, Thomas J Brady.   

Abstract

BACKGROUND: Important to the risk stratification and management of cardiac patients is the assessment of left ventricular function (LVEF), thus imaging modalities which can provide both anatomical and functional data is desirable. Electrocardiographic (ECG) gated multi-detector computed tomographic (MDCT) images may provide accurate assessment of LV ejection fraction, volume and dimensions but have shown systemic errors in the past due to slow gantry rotation speed.
METHODS: Between May 2004 and January 2005, 306 patients underwent ECG-gated cardiac CT studies at the Massachusetts General Hospital. Patients with available CT data sets and a recent (within 3 months) ECHO and/or SPECT perfusion imaging were included in the study. ECG-gated data sets were acquired either with a 16-slice or with a 64-slice MDCT. Functional MDCT data sets were reconstructed in 10 cardiac phases (5-95%) with 1.5mm slices. Images were processed and interpreted by two observers blinded to ECHO and SPECT results.
RESULTS: A total of 69 patients had MDCT and ECHO or SPECT within 3 months (33 had 16-slice and 36 had 64-slice MDCT). There was fair correlation between LVEF measured by 16-slice MDCT and 'ECHO or SPECT' (62+/-10% vs. 62+/-10%; r=0.56). There was poor correlation between LVEF measured by 16-slice MDCT and ECHO (64+/-10% vs. 59+/-11%; r=0.26) and there was good correlation between LVEF measured by 16-slice MDCT and SPECT (62+/-11% and 64+/-9%, respectively; r=0.76). There was very good correlation between LVEF measured by 64-slice MDCT and 'ECHO or SPECT' (57+/-15% vs. 58+/-13%; r=0.86). There was very good correlation between LVEF measured by MDCT and ECHO (56+/-14% vs. 54+/-15%; r=0.89) and between LVEF measured by 64-slice MDCT and SPECT (60+/-13% and 60+/-14%, respectively; r=0.90).
CONCLUSION: The assessment of LVEF and LV dimensions with 64-slice MDCT provide values which are similar to those obtained by echocardiography and Tc-99m gated SPECT. The accuracy of the 64-slice MDCT with a gantry rotation speed of 330 ms (when compared to ECHO and SPECT) may be superior to that of the 16-slice MDCT at 420 ms gantry rotation.

Entities:  

Mesh:

Year:  2007        PMID: 17826936     DOI: 10.1016/j.ejrad.2007.07.022

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  10 in total

1.  Functional parameters of the left ventricle: comparison of cardiac MRI and cardiac CT in a large population.

Authors:  A Palumbo; E Maffei; C Martini; G Messalli; S Seitun; R Malagò; A Aldrovandi; E Emiliano; A Cuttone; A Weustink; N Mollet; F Cademartiri
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

Review 2.  CT for assessing ventricular remodeling: is it ready for prime time?

Authors:  Gardar Sigurdsson
Journal:  Curr Heart Fail Rep       Date:  2008-03

3.  Assessment of left ventricular ejection fraction using low radiation dose computed tomography.

Authors:  YiQi Yang; Yeung Yam; Li Chen; Ahmed Aljizeeri; Siamak Aliyary Ghraboghly; Ibraheem Al-Harbi; Ally Pen; Terrence D Ruddy; Benjamin J W Chow
Journal:  J Nucl Cardiol       Date:  2015-05-22       Impact factor: 5.952

4.  Assessment of left ventricular volumes, ejection fraction and regional wall motion with retrospective electrocardiogram triggered 320-detector computed tomography: a comparison with 2D-echocardiography.

Authors:  Arthur Nasis; Stuart Moir; Sujith K Seneviratne; James D Cameron; Philip M Mottram
Journal:  Int J Cardiovasc Imaging       Date:  2011-06-11       Impact factor: 2.357

5.  Effects of propranolol on the left ventricular volume of normal subjects during CT coronary angiography.

Authors:  Yuan Heng Mo; Fu Shan Jaw; Yung Cheng Wang; Chin Ming Jeng; Shinn Forng Peng
Journal:  Korean J Radiol       Date:  2011-04-25       Impact factor: 3.500

6.  The Association Between the Use of Low-Slice Computed Tomography Machines and Downstream Care: Comparative Study of 16-Slice and 64-Slice Computed Tomography Angiography.

Authors:  Adam C Powell; James W Long; Uday U Deshmukh; Jeffrey D Simmons
Journal:  JMIR Form Res       Date:  2022-06-30

7.  Assessment of left ventricular ejection fraction and regional wall motion with 64-slice multidetector CT: a comparison with two-dimensional transthoracic echocardiography.

Authors:  S-M Ko; Y-J Kim; J-H Park; N-M Choi
Journal:  Br J Radiol       Date:  2009-06-22       Impact factor: 3.039

8.  Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR.

Authors:  Erica Maffei; Giancarlo Messalli; Chiara Martini; Koen Nieman; Onofrio Catalano; Alexia Rossi; Sara Seitun; Andrea I Guaricci; Carlo Tedeschi; Nico R Mollet; Filippo Cademartiri
Journal:  Eur Radiol       Date:  2012-01-24       Impact factor: 5.315

9.  Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose.

Authors:  Ji Won Lee; Kyung Jin Nam; Jin You Kim; Yeon Joo Jeong; Geewon Lee; So Min Park; Soo Jin Lim; Ki Seok Choo
Journal:  J Cardiovasc Imaging       Date:  2019-11-20

10.  Clinical Utility of Third-generation Dual-source Computed Tomography for Left Ventricular Function Analysis and Coronary Artery Evaluation with Minimal Radiation Exposure.

Authors:  Min Jae Cha
Journal:  J Cardiovasc Imaging       Date:  2020-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.