Literature DB >> 17826788

Analysis of 1-nitropyrene in air particulate matter standard reference materials by using two-dimensional high performance liquid chromatography with online reduction and tandem mass spectrometry detection.

Justin P Miller-Schulze1, Michael Paulsen, Akira Toriba, Kazuichi Hayakawa, Christopher D Simpson.   

Abstract

1-Nitropyrene (1-NP) is enriched in diesel exhaust particulate matter (DPM) relative to other sources of particulate matter (PM), and has been proposed as a marker for DPM. However, in ambient air, 1-NP concentrations are typically in the low pg/m(3) range. Therefore, collection of large volume air samples coupled with extensive sample clean-up procedures has been required to achieve adequate detection limits to measure 1-NP in ambient samples. We report here an improved LC-MS/MS method suitable for the detection and quantification of 1-NP in low volume ambient PM samples. The method involves ultrasonic extraction of ambient PM in organic solvent, concentration of the sample under reduced pressure, and two-dimensional HPLC analysis of the extract. 1-NP is isolated on the first HPLC column, then converted to 1-aminopyrene (1-AP) via online reduction in a column packed with a Pt/Rh catalyst. The 1-AP containing fraction from the first column is refocused on a trapping column, then eluted through a second HPLC column prior to MS/MS detection. Deuterated (d(9)) 1-NP (1-dNP) is added to each sample prior to extraction as an internal standard for quantification of 1-NP. The accuracy and precision of the assay, as applied to ambient particulate standard reference materials are 110+/-5.7% for SRM 1650b, 116+/-7.1% for SRM 2975, 108+/-5.8% for SRM 1649a, and 53+/-9.2% for SRM 1648. The analytical limit of detection was 152 fg on column, and analytical limit of quantitation 221 fg on column. To our knowledge, the sensitivity of this method is comparable with GC-NICI-MS methods while having the advantage of considerably less extensive sample preparation. This method is an approximately 10-fold improvement in sensitivity over HPLC methods utilizing fluorescence and/or chemiluminescence detection.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17826788     DOI: 10.1016/j.chroma.2007.08.026

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Evaluation of 1-Nitropyrene as a Surrogate Measure for Diesel Exhaust.

Authors:  Erin A Riley; Emily E Carpenter; Joemy Ramsay; Emily Zamzow; Christopher Pyke; Michael H Paulsen; Lianne Sheppard; Terry M Spear; Noah S Seixas; Dale J Stephenson; Christopher D Simpson
Journal:  Ann Work Expo Health       Date:  2018-03-12       Impact factor: 2.179

2.  Factors and Trends Affecting the Identification of a Reliable Biomarker for Diesel Exhaust Exposure.

Authors:  David A Morgott
Journal:  Crit Rev Environ Sci Technol       Date:  2014-08       Impact factor: 12.561

3.  Exposures to particulate air pollution and nitro-polycyclic aromatic hydrocarbons among taxi drivers in Shenyang, China.

Authors:  Justin P Miller-Schulze; Michael Paulsen; Akira Toriba; Ning Tang; Kazuichi Hayakawa; Kenji Tamura; Lijun Dong; Xuemei Zhang; Christopher D Simpson
Journal:  Environ Sci Technol       Date:  2010-01-01       Impact factor: 9.028

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.