Literature DB >> 17826271

The use of plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy in the diagnosis of a loose acetabular component of a total hip prosthesis: a systematic review.

Olivier P P Temmerman1, Pieter G H M Raijmakers, Walter L Deville, Johannes Berkhof, Lotty Hooft, Ide C Heyligers.   

Abstract

This meta-analysis was performed to summarize and compare the diagnostic performance and diagnostic accuracy of radiographic and scintigraphic techniques in the evaluation of patients suspected of having aseptically loose acetabular components. Twenty-eight studies, published between January 1975 and October 2004, presented sufficient data for quantitative analysis. The pooled sensitivity and specificity rates for plain radiography were 70% (95% confidence interval [CI] = 59%-79%) and 80% (95% CI = 73%-86%), respectively; those for subtraction arthrography were 89% (95% CI = 84%-93%) and 76% (95% CI = 68%-82%), respectively; and those for nuclear arthrography were 87% (95% CI = 57%-97%) and 64% (95% CI = 40%-82%), respectively. Finally, bone scintigraphy had a sensitivity of 67% (95% CI = 57%-76%) and a specificity of 75% (95% CI = 64%-83%). We found a significantly higher sensitivity for subtraction arthrography as compared with plain radiography and bone scintigraphy. Therefore, subtraction arthrography is recommended for use as an additional diagnostic technique when plain radiography is found to be inconclusive.

Entities:  

Mesh:

Year:  2007        PMID: 17826271     DOI: 10.1016/j.arth.2006.08.004

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Personalized image-based templates for precise acetabular prosthesis placement in total hip arthroplasty: a pilot study.

Authors:  Bin Chen; Sheng-xiang Xiao; Peng-cheng Gu; Xiang-jin Lin
Journal:  J Zhejiang Univ Sci B       Date:  2010-09       Impact factor: 3.066

2.  Hybrid SPECT/CT for the assessment of a painful hip after uncemented total hip arthroplasty.

Authors:  Oliver Dobrindt; Holger Amthauer; Alexander Krueger; Juri Ruf; Heiko Wissel; Oliver S Grosser; Max Seidensticker; Christoph H Lohmann
Journal:  BMC Med Imaging       Date:  2015-06-02       Impact factor: 1.930

Review 3.  What is the Accuracy of Nuclear Imaging in the Assessment of Periprosthetic Knee Infection? A Meta-analysis.

Authors:  Steven J Verberne; Remko J A Sonnega; Olivier P P Temmerman; Pieter G Raijmakers
Journal:  Clin Orthop Relat Res       Date:  2017-01-03       Impact factor: 4.176

4.  The diagnostic accuracy of radionuclide arthrography for prosthetic loosening in hip and knee arthroplasty.

Authors:  Timothy H French; Nicholas Russell; Anand Pillai
Journal:  Biomed Res Int       Date:  2013-07-15       Impact factor: 3.411

5.  Higher reliability of triple-phase bone scintigraphy in cementless total hip arthroplasty compared to cementless bipolar hemiarthroplasty.

Authors:  Burak Yoldas; Deniz Cankaya; Kemal Andic; Enver Kilic; Olgun Bingol; Ali Tecirli; Ali Toprak; Yalçın Tabak
Journal:  Ann Med Surg (Lond)       Date:  2016-07-26

6.  Consensus document for the diagnosis of prosthetic joint infections: a joint paper by the EANM, EBJIS, and ESR (with ESCMID endorsement).

Authors:  Alberto Signore; Luca Maria Sconfienza; Olivier Borens; Andor W J M Glaudemans; Victor Cassar-Pullicino; Andrej Trampuz; Heinz Winkler; Olivier Gheysens; Filip M H M Vanhoenacker; Nicola Petrosillo; Paul C Jutte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-01-26       Impact factor: 9.236

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.