Literature DB >> 17825572

Radiation shielding evaluation of the BNCT treatment room at THOR: a TORT-coupled MCNP Monte Carlo simulation study.

A Y Chen1, Y-W H Liu, R J Sheu.   

Abstract

This study investigates the radiation shielding design of the treatment room for boron neutron capture therapy at Tsing Hua Open-pool Reactor using "TORT-coupled MCNP" method. With this method, the computational efficiency is improved significantly by two to three orders of magnitude compared to the analog Monte Carlo MCNP calculation. This makes the calculation feasible using a single CPU in less than 1 day. Further optimization of the photon weight windows leads to additional 50-75% improvement in the overall computational efficiency.

Entities:  

Mesh:

Year:  2007        PMID: 17825572     DOI: 10.1016/j.apradiso.2007.07.016

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  1 in total

1.  Assessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation.

Authors:  M Kazempour; M Saeedimoghadam; F Shekoohi Shooli; N Shokrpour
Journal:  J Biomed Phys Eng       Date:  2015-06-01
  1 in total