Literature DB >> 17822922

Bilateral edge filter: photometrically weighted, discontinuity based edge detection.

Radosav S Pantelic1, Geoffery Ericksson, Nicholas Hamilton, Ben Hankamer.   

Abstract

Edge-detection algorithms have the potential to play an increasingly important role both in single particle analysis (for the detection of randomly oriented particles), and in tomography (for the segmentation of 3D volumes). However, the majority of traditional linear filters are significantly affected by noise as well as artefacts, and offer limited selectivity. The Bilateral edge filter presented here is an adaptation of the Bilateral filter [Jiang, W., Baker, M.L., Wu, Q., Bajaj, C., Chiu, W., 2003. Applications of a bilateral denoising filter in biological electron microscopy. J. Struct. Biol. 144, 114-122] designed for enhanced edge detection. It uses photometric weighting to identify significant discontinuities (representing edges), minimizing artefacts and noise. Compared with common edge-detectors (LoG, Marr-Hildreth) the Bilateral edge filter yielded significantly better results. Indeed data was of a similar quality to that of the Canny edge-detector, which is considered as a leading standard in edge detection [Basu, M., 2002. Gaussian-based edge-detection methods-a survey. IEEE Trans. Syst. Man Cybern. C Appl. Rev. 32, 252-260]. Compared to the Canny edge-detector the Bilateral edge-detector has the advantages that it only requires the adjustment of a single parameter, is theoretically faster for reasonably sized images, and can be used in selective contrast enhancement of images. The simplicity and speed of the filter for single particle and tomographic analysis are discussed.

Entities:  

Mesh:

Year:  2007        PMID: 17822922     DOI: 10.1016/j.jsb.2007.07.005

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  5 in total

1.  Collagen fibril morphology and mechanical properties of the Achilles tendon in two inbred mouse strains.

Authors:  S Rigozzi; R Müller; J G Snedeker
Journal:  J Anat       Date:  2010-03-23       Impact factor: 2.610

2.  A validated active contour method driven by parabolic arc model for detection and segmentation of mitochondria.

Authors:  Serdar F Tasel; Erkan U Mumcuoglu; Reza Z Hassanpour; Guy Perkins
Journal:  J Struct Biol       Date:  2016-03-05       Impact factor: 2.867

3.  [Progress in filters for denoising cryo-electron microscopy images].

Authors:  X R Huang; S Li; S Gao
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2021-03-03

4.  A 3D image filter for parameter-free segmentation of macromolecular structures from electron tomograms.

Authors:  Rubbiya A Ali; Michael J Landsberg; Emily Knauth; Garry P Morgan; Brad J Marsh; Ben Hankamer
Journal:  PLoS One       Date:  2012-03-29       Impact factor: 3.240

Review 5.  Molecular electron microscopy: state of the art and current challenges.

Authors:  Henning Stahlberg; Thomas Walz
Journal:  ACS Chem Biol       Date:  2008-05-16       Impact factor: 5.100

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.