Literature DB >> 17822003

Quality assurance of the multileaf collimator with helical tomotherapy: design and implementation.

Vikren Sarkar1, Lan Lin, Chengyu Shi, Niko Papanikolaou.   

Abstract

Quality assurance (QA) of the multileaf collimator (MLC) is a critical step for the delivery of intensity modulated radiation therapy treatment plan. While QA procedures for motor-driven MLC have been published extensively, those for binary MLCs such as the one used for helical tomotherapy have not been presented in the literature, as this is still a fairly new technology. In this study, seven test patterns for the MLC QA of a helical tomotherapy unit have been designed and implemented. The seven test patterns check the MLC alignment, MLC leakage, MLC timing and MLC leaf position error in detail. Those patterns can be easily implemented in any center with a helical tomotherapy unit as part of the routine QA. The QA procedures can be performed using existing QA resources such as solid water phantom and EDR2 film. A software toolkit called "Tomo MLC QA" has been developed to assist in generating the QA procedures and analyzing the results. Our results showed that the helical tomotherapy MLC is very robust, exhibiting interleaf leakage of 0.53% +/-0.09%. Several issues with the MLC have been found and discussed. The QA results also illustrate the utilization and usefulness of the proposed QA procedures.

Entities:  

Mesh:

Year:  2007        PMID: 17822003     DOI: 10.1118/1.2748105

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Empirical estimation of beam-on time for prostate cancer patients treated on Tomotherapy.

Authors:  Małgorzata Skórska; Tomasz Piotrowski
Journal:  Rep Pract Oncol Radiother       Date:  2013-02-04

2.  A quality assurance tool for helical tomotherapy using a step-wedge phantom and the on-board MVCT detector.

Authors:  Vincent Althof; Paul van Haaren; Rik Westendorp; Tonnis Nuver; Dinant Kramer; Marijke Ikink; Arjen Bel; Andre Minken
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

3.  Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma.

Authors:  Sang Gyu Ju; Yong Chan Ahn; Yeong-Bi Kim; Jin Man Kim; Dong Yeol Kwon; Byoung Suk Park; Kyungmi Yang
Journal:  Radiat Oncol       Date:  2022-09-12       Impact factor: 4.309

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.