Twenty-six patients undergoing middle ear surgery were anaesthetised using a completely closed circuit into which liquid isoflurane was injected using a syringe pump. The injection rate was guided by a table of calculated rates of isoflurane uptake, utilising the square root of time principle, at succeeding time intervals in different weight groups. A constant alveolar concentration of 1.3 MAC was aimed for. The injection rate was changed to that for the higher or lower weight group appropriate to the time interval whenever clinical signs indicated inappropriate depth of anaesthesia. A mean of 10.3 ml liquid isoflurane was used to maintain anaesthesia for a mean of 82.3 minutes. Blood pressure was maintained at 75% of the pre-operative value. Mean arterial blood gas data and changes in plasma catecholamine levels were within the normal range. The mean recovery time was 10.5 minutes. Syringe pump delivery of liquid isoflurane avoided fluctuations that result from bolus injections of unit dose. The implemented injection rate table, working as a therapeutic window, guided redosing, reduced calculation time and served as a record. The technique is safe, economic and adaptable to variations in uptake and response to inhalational anaesthetics.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1781534     DOI: 10.1111/j.1365-2044.1991.tb09924.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents.

Authors:  Krista Bigiarelli; Luke E Schepers; Arvin H Soepriatna; Dave FitzMiller; Craig J Goergen
Journal:  J Vis Exp       Date:  2020-07-09       Impact factor: 1.355

2.  Linear approximation of Brody's equation to predict oxygen consumption.

Authors:  R Kennedy
Journal:  J Clin Monit       Date:  1996-01

3.  Use of a Low-flow Digital Anesthesia System for Mice and Rats.

Authors:  Amelia R Adelsperger; Krista J Bigiarelli-Nogas; Irina Toore; Craig J Goergen
Journal:  J Vis Exp       Date:  2016-09-07       Impact factor: 1.355

4.  A simple method for evaluation of the uptake of isoflurane and its comparison with the square root of time model.

Authors:  Ashish Bangaari; Nidhi Bidyut Panda; Goverdhan Dutt Puri
Journal:  Indian J Anaesth       Date:  2013-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.