Literature DB >> 17804880

Enhancement of subharmonic emission from encapsulated microbubbles by using a chirp excitation technique.

Dong Zhang1, Yanjun Gong, Xiufen Gong, Zheng Liu, Kaibin Tan, Hairong Zheng.   

Abstract

Subharmonic contrast imaging promises to improve ultrasound-imaging quality by taking advantage of an increased contrast to tissue signal. However, acoustic pressures beyond the subharmonic generation threshold using common ultrasound pulses may induce significant contrast microbubble destruction. In this work, a chirp excitation technique is presented to enhance the subharmonic emission from encapsulated microbubbles. Chirp signals with a center frequency of 5 MHz, variable frequency range and duration time are employed to drive microbubbles in numerical simulation and experimental studies. We provide a theoretical evaluation of the chirp excitation pressure threshold and the acoustic pressure dependence of subharmonic based on Church's model and demonstrate that the amplitude and axial resolution of the subharmonic can be optimized by proper selection of the frequency range and time duration of the chirp signal. Measurements are qualitatively in agreement with the simulation. Moreover, we demonstrate that chirp excitation may be able to improve the amplitude of the subharmonic component up to 22 dB over the pulse excitation. The chirp excitation technique could potentially be used for improving the subharmonic contrast imaging quality.

Mesh:

Substances:

Year:  2007        PMID: 17804880     DOI: 10.1088/0031-9155/52/18/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Improving the sensitivity of high-frequency subharmonic imaging with coded excitation: a feasibility study.

Authors:  Himanshu Shekhar; Marvin M Doyley
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging.

Authors:  Himanshu Shekhar; Joshua J Rychak; Marvin M Doyley
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

3.  The response of phospholipid-encapsulated microbubbles to chirp-coded excitation: implications for high-frequency nonlinear imaging.

Authors:  Himanshu Shekhar; Marvin M Doyley
Journal:  J Acoust Soc Am       Date:  2013-05       Impact factor: 1.840

4.  Combining Subharmonic and Ultraharmonic Modes for Intravascular Ultrasound Imaging: A Preliminary Evaluation.

Authors:  Himanshu Shekhar; Jeffrey S Rowan; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2017-08-26       Impact factor: 2.998

5.  Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array.

Authors:  Anthony Novell; Christopher B Arena; Sandeep Kasoji; Paul A Dayton
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

6.  The delayed onset of subharmonic and ultraharmonic emissions from a phospholipid-shelled microbubble contrast agent.

Authors:  Himanshu Shekhar; Ivy Awuor; Keri Thomas; Joshua J Rychak; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2014-04       Impact factor: 2.998

7.  Effect of Pulse Shaping on Subharmonic Aided Pressure Estimation In Vitro and In Vivo.

Authors:  Ipshita Gupta; John Eisenbrey; Maria Stanczak; Anush Sridharan; Jaydev K Dave; Ji-Bin Liu; Christopher Hazard; Xinghua Wang; Ping Wang; Huiwen Li; Kirk Wallace; Flemming Forsberg
Journal:  J Ultrasound Med       Date:  2016-12-10       Impact factor: 2.153

8.  Developing an Interface and Investigating Optimal Parameters for Real-Time Intracardiac Subharmonic-Aided Pressure Estimation.

Authors:  Cara Esposito; Kris Dickie; Flemming Forsberg; Jaydev K Dave
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.