A rebinned backprojection-filtration algorithm for image reconstruction in helical cone-beam CT.

Lifeng Yu1, Dan Xia, Yu Zou, Emil Y Sidky, Junguo Bian, Xiaochuan Pan.   

Abstract

In the last few years, mathematically exact algorithms, including the backprojection-filtration (BPF) algorithm, have been developed for accurate image reconstruction in helical cone-beam CT. The BPF algorithm requires minimum data, and can reconstruct region-of-interest (ROI) images from data containing truncations. However, similar to other existing reconstruction algorithms for helical cone-beam CT, the BPF algorithm involves a backprojection with a spatially varying weighting factor, which is computationally demanding and, more importantly, can lead to undesirable numerical properties in reconstructed images. In this work, we develop a rebinned BPF algorithm in which the backprojection invokes no spatially varying weighting factor for accurate image reconstruction from helical cone-beam projections. This rebinned BPF algorithm is computationally more efficient and numerically more stable than the original BPF algorithm, while it also retains the nice properties of the original BPF algorithm such as minimum data requirement and ROI-image reconstruction from truncated data. We have also performed simulation studies to validate and evaluate the rebinned BPF algorithm.

Mesh:

Year:  2007        PMID: 17804878     DOI: 10.1088/0031-9155/52/18/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Reconstructing cone-beam CT with spatially varying qualities for adaptive radiotherapy: a proof-of-principle study.

Authors:  Wenting Lu; Hao Yan; Xuejun Gu; Zhen Tian; Ouyang Luo; Liu Yang; Linghong Zhou; Laura Cervino; Jing Wang; Steve Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2014-09-26       Impact factor: 3.609

2.  Region of Interest Imaging for a General Trajectory with the Rebinned BPF Algorithm.

Authors:  Junguo Bian; Dan Xia; Emil Y Sidky; Xiaochuan Pan
Journal:  Tsinghua Sci Technol       Date:  2010-02       Impact factor: 2.016

3.  Accurate helical cone-beam CT reconstruction with redundant data.

Authors:  Harald Schöndube; Karl Stierstorfer; Frédéric Noo
Journal:  Phys Med Biol       Date:  2009-07-10       Impact factor: 3.609

4.  Half-Fan-Based Intensity-Weighted Region-of-Interest Imaging for Low-Dose Cone-Beam CT in Image-Guided Radiation Therapy.

Authors:  Boyeol Yoo; Kihong Son; Rizza Pua; Jinsung Kim; Alexander Solodov; Seungryong Cho
Journal:  Healthc Inform Res       Date:  2016-10-31
  4 in total