Literature DB >> 17804771

Adjunctive use of C-arm CT may eliminate technical failure in adrenal vein sampling.

Christos S Georgiades1, Kelvin Hong, Jean-Francois Geschwind, Robert Liddell, Labib Syed, Julia Kharlip, Aravind Arepally.   

Abstract

PURPOSE: To examine whether the use of C-arm computed tomography (CT) during adrenal vein sampling improves the technical success rate of the procedure.
MATERIALS AND METHODS: Nine consecutive patients with suspected primary hyperaldosteronism underwent standard adrenal vein sampling that included cortisol stimulation. The procedure was augmented with multiplanar C-arm CT images reconstructed from data acquired during a 180 degrees C-arm rotation. Whenever C-arm CT images showed the sampling catheter to be in the wrong position, the catheter was repositioned. Cortisol response was correlated to C-arm CT findings.
RESULTS: All patients had successful and diagnostic adrenal vein sampling. C-arm CT showed sampling catheter malposition in two patients (22%). Repeat C-arm CT after repositioning showed proper catheter location. Cortisol stimulation results and C-arm CT findings were concordant in 100% of cases.
CONCLUSIONS: C-arm CT is reliable in confirming the location of sampling catheters during adrenal vein sampling. If the 100% concordance between cortisol stimulation and C-arm CT findings is found in larger groups, the technical success rate may approach 100%. Cortisol stimulation may become obsolete and repeat procedures unnecessary, with significant time and cost savings.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17804771     DOI: 10.1016/j.jvir.2007.06.018

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  12 in total

1.  Adrenal hormones before and after venography during adrenal venous sampling: a self-controlled study.

Authors:  Yuya Koike; Seishi Matsui; Masao Omura; Kohzoh Makita; Alfonso W D Obara; Nobukazu Moriya; Tetsuo Nishikawa
Journal:  Jpn J Radiol       Date:  2017-01-10       Impact factor: 2.374

2.  Visualization of the right adrenal vein using CT during right inferior phrenic arteriography in hepatocellular carcinoma patients.

Authors:  Sota Oguro; Seishi Nakatsuka; Masahiro Jinzaki; Manabu Misu; Hideki Yashiro; Subaru Hashimoto; Sachio Kuribayashi
Journal:  Jpn J Radiol       Date:  2014-09-24       Impact factor: 2.374

3.  Can an enhanced thin-slice computed tomography delineate the right adrenal vein and improve the success rate?

Authors:  Shiro Onozawa; Satoru Murata; Hidenori Yamaguchi; Takahiko Mine; Daisuke Yasui; Hitoshi Sugihara; Hiroyuki Tajima
Journal:  Jpn J Radiol       Date:  2016-07-06       Impact factor: 2.374

4.  Comparison of C-arm computed tomography and on-site quick cortisol assay for adrenal venous sampling: A retrospective study of 178 patients.

Authors:  Chin-Chen Chang; Bo-Ching Lee; Yeun-Chung Chang; Vin-Cent Wu; Kuo-How Huang; Kao-Lang Liu
Journal:  Eur Radiol       Date:  2017-07-04       Impact factor: 5.315

Review 5.  [Use of C-arm CT for improving the hit rate for selective blood sampling from adrenal veins].

Authors:  C Georgiades; J Kharlip; S Valdeig; F K Wacker; K Hong
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

6.  Does catheter shape influence the success of right adrenal venous sampling? The interaction of catheter shape to anatomical factors on CT.

Authors:  Takuji Araki; Hiroki Okada; Hiroshi Onishi
Journal:  Jpn J Radiol       Date:  2016-09-20       Impact factor: 2.374

7.  A New Spin on Adrenal Vein Sampling.

Authors:  Scott O Trerotola
Journal:  Cardiovasc Intervent Radiol       Date:  2021-10-03       Impact factor: 2.740

Review 8.  Role of C-arm cone-beam CT in chemoembolization for hepatocellular carcinoma.

Authors:  Hyo-Cheol Kim
Journal:  Korean J Radiol       Date:  2015-01-09       Impact factor: 3.500

9.  Non-stimulated adrenal venous sampling using Dyna computed tomography in patients with primary aldosteronism.

Authors:  Chin-Chen Chang; Bo-Ching Lee; Kao-Lang Liu; Yeun-Chung Chang; Vin-Cent Wu; Kuo-How Huang
Journal:  Sci Rep       Date:  2016-11-23       Impact factor: 4.379

10.  C-Arm Computed Tomography-Assisted Adrenal Venous Sampling Improved Right Adrenal Vein Cannulation and Sampling Quality in Primary Aldosteronism.

Authors:  Chung Hyun Park; Namki Hong; Kichang Han; Sang Wook Kang; Cho Rok Lee; Sungha Park; Yumie Rhee
Journal:  Endocrinol Metab (Seoul)       Date:  2018-05-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.