Literature DB >> 1779732

Improvement of 3D acquisition and visualization in MRI.

M Bomans1, K H Höhne, G Laub, A Pommert, U Tiede.   

Abstract

Three-dimensional (3D) visualization techniques are becoming an ever more important aid in the interpretation of tomographic data. Up to now, however, they have not received widespread use in MRI, because both acquisition and visualization techniques have been inadequate. In this paper we describe new 3D acquisition techniques which can acquire up to 128 slices with a resolution of 256 x 256 pixels in from 8 to 20 min. These techniques produce 3D data sets with excellent contrast and few motion artifacts, which are very well suited for 3D visualization techniques. For the visualization we investigate several rendering techniques, describe some improvements and compare their results. We found that there is no single method which renders all objects equally well. We show which shading method is best suited for different objects and why the other methods fail. Our studies suggest that in a 3D view with several objects each object should be rendered with a separate shading method. In so doing, 3D views can be generated which look like the real human anatomy.

Entities:  

Mesh:

Year:  1991        PMID: 1779732     DOI: 10.1016/0730-725x(91)90048-q

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

1.  Real-time volume rendered MRI for interventional guidance.

Authors:  Michael A Guttman; Robert J Lederman; Jonathan M Sorger; Elliot R McVeigh
Journal:  J Cardiovasc Magn Reson       Date:  2002       Impact factor: 5.364

2.  Three-dimensional reconstructions of carotid bifurcation from CT images: evaluation of different rendering methods.

Authors:  Z Tarjàn; F Pozzi Mucelli; F Frezza; R Pozzi Mucelli
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

3.  A PC-based workstation for processing and analysis of MRI data.

Authors:  P Marzola; A Da Pra; A Sbarbati; F Osculati
Journal:  MAGMA       Date:  1998-11       Impact factor: 2.310

4.  Comparative study of 3D-SPGR vs 2D-SE T1WI after enhancement in the brain.

Authors:  Wenzhen Zhu; Jianpin Qi; Chengyuan Wang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2003

5.  Ultrafast 3D spin-echo acquisition improves Gadolinium-enhanced MRI signal contrast enhancement.

Authors:  S H Han; F H Cho; Y K Song; J Paulsen; Y Q Song; Y R Kim; J K Kim; G Cho; H Cho
Journal:  Sci Rep       Date:  2014-05-27       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.