Literature DB >> 1778039

Studies on the effect of the third dimension on a two-dimensional electrical impedance tomography system.

K S Rabbani1, A M Kabir.   

Abstract

This work is based on the Applied Potential Tomography (APT) system developed in Sheffield and the results specifically relate to this system. Using a cylindrical phantom containing saline, the effects of extended layers in the third dimension on the two-dimensional tomographic images have been studied. Experimentally obtained magnitudes of pixel values corresponding to different conditions in the third dimension are presented. Analysis of these data brings out two phenomena: (i) layers of changed resistivity out of the electrode plane can appear as both increased and decreased resistivity in the image; and (ii) the position of the maximum resistivity change in the image occurs at increasing distances from the edge of the phantom, as the layers of resistivity change are introduced further from the electrode plane and they have a one to one relationship. An intuitive interpretation related to perturbation of equicurrent surfaces in the third dimension has been suggested to explain these phenomena.

Entities:  

Mesh:

Year:  1991        PMID: 1778039     DOI: 10.1088/0143-0815/12/4/009

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  12 in total

1.  Body and head position effects on regional lung ventilation in infants: An electrical impedance tomography study.

Authors:  Sina Heinrich; Holger Schiffmann; Alexander Frerichs; Adelbert Klockgether-Radke; Inéz Frerichs
Journal:  Intensive Care Med       Date:  2006-06-24       Impact factor: 17.440

2.  A new six-electrode electrical impedance technique for probing deep organs in the human body.

Authors:  Shamor Kanti Roy; Mohammad Abu Sayem Karal; Muhammad Abdul Kadir; Khondkar Siddique-E Rabbani
Journal:  Eur Biophys J       Date:  2019-09-16       Impact factor: 1.733

3.  Estimating regions of air trapping from electrical impedance tomography data.

Authors:  Jennifer L Mueller; Peter Muller; Michelle Mellenthin; Rashmi Murthy; Michael Capps; Melody Alsaker; Robin Deterding; Scott D Sagel; Emily DeBoer
Journal:  Physiol Meas       Date:  2018-05-31       Impact factor: 2.833

4.  A Three Dimensional Calderon-Based Method for EIT on the Cylindrical Geometry.

Authors:  Kwancheol Shin; Sanwar Uddin Ahmad; Jennifer L Mueller
Journal:  IEEE Trans Biomed Eng       Date:  2021-04-21       Impact factor: 4.538

5.  Effect of PEEP and tidal volume on ventilation distribution and end-expiratory lung volume: a prospective experimental animal and pilot clinical study.

Authors:  Günther Zick; Gunnar Elke; Tobias Becher; Dirk Schädler; Sven Pulletz; Sandra Freitag-Wolf; Norbert Weiler; Inéz Frerichs
Journal:  PLoS One       Date:  2013-08-22       Impact factor: 3.240

6.  Short-term effects of neuromuscular blockade on global and regional lung mechanics, oxygenation and ventilation in pediatric acute hypoxemic respiratory failure.

Authors:  Marlon E F Wilsterman; Pauline de Jager; Robert Blokpoel; Inez Frerichs; Sandra K Dijkstra; Marcel J I J Albers; Johannes G M Burgerhof; Dick G Markhorst; Martin C J Kneyber
Journal:  Ann Intensive Care       Date:  2016-10-26       Impact factor: 6.925

7.  Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group.

Authors:  Inéz Frerichs; Marcelo B P Amato; Anton H van Kaam; David G Tingay; Zhanqi Zhao; Bartłomiej Grychtol; Marc Bodenstein; Hervé Gagnon; Stephan H Böhm; Eckhard Teschner; Ola Stenqvist; Tommaso Mauri; Vinicius Torsani; Luigi Camporota; Andreas Schibler; Gerhard K Wolf; Diederik Gommers; Steffen Leonhardt; Andy Adler
Journal:  Thorax       Date:  2016-09-05       Impact factor: 9.139

Review 8.  Electrical Impedance Tomography for Cardio-Pulmonary Monitoring.

Authors:  Christian Putensen; Benjamin Hentze; Stefan Muenster; Thomas Muders
Journal:  J Clin Med       Date:  2019-08-07       Impact factor: 4.241

9.  Probing for Stomach using the Focused Impedance Method (FIM).

Authors:  Rashida Haque; Muhammad Abdul Kadir; K Siddique-E Rabbani
Journal:  J Electr Bioimpedance       Date:  2019-12-26

10.  Dynamics of regional lung aeration determined by electrical impedance tomography in patients with acute respiratory distress syndrome.

Authors:  Sven Pulletz; Matthias Kott; Gunnar Elke; Dirk Schädler; Barbara Vogt; Norbert Weiler; Inéz Frerichs
Journal:  Multidiscip Respir Med       Date:  2012-11-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.