Literature DB >> 17768705

Analyses of macrolide antibiotic residues in eggs, raw milk, and honey using both ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry and high-performance liquid chromatography/tandem mass spectrometry.

Jian Wang1, Daniel Leung.   

Abstract

Two liquid chromatography mass spectrometric techniques, i.e. ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/Q-Tof MS) and high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS), were used for quantification, confirmation or identification of six macrolide antibiotic residues and/or their degradation products in eggs, raw milk, and/or honey. Macrolides were extracted from food samples by acetonitrile or phosphate buffer (0.1 M, pH 8.0), and sample extracts were further cleaned up using solid-phase extraction cartridges. UPLC/Q-Tof data were acquired in Tof MS full scan mode that allowed both quantification and confirmation of macrolides, and identification of their degradation products. LC/MS/MS data acquisition was achieved using multiple reaction monitoring (MRM), i.e. two transitions, to provide a high degree of sensitivity and repeatability. Matrix-matched standard calibration curves with the use of roxithromycin as an internal standard were utilized to achieve the best accuracy of the method. Both techniques demonstrated good quantitative performance in terms of accuracy and repeatability. LC/MS/MS had advantages over UPLC/Q-Tof MS in that its limits of detection were lower and repeatability was somewhat better. UPLC/Q-Tof provided ultimate and unequivocal confirmation of positive findings, and allowed degradation product identification based on accurate mass. The combination of the two techniques can be very beneficial or complementary in routine analysis of macrolide antibiotic residues and their degradation products in food matrices to ensure the safety of food supply. Copyright (c) 2007 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17768705     DOI: 10.1002/rcm.3207

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

1.  Challenges for the determination of spiramycin in aqueous matrices using LC-MS/MS: evidence for the solvent intrusion on the molecule integrity.

Authors:  Azadeh Nasiri; Shaya Mokhtari; Reza Jahani; Bahram Daraie; Hassan Yazdanpanah; Mehrdad Faizi; Farzad Kobarfard
Journal:  RSC Adv       Date:  2022-06-09       Impact factor: 4.036

2.  Identification and profiling of targeted oxidized linoleic acid metabolites in rat plasma by quadrupole time-of-flight mass spectrometry.

Authors:  Zhi-Xin Yuan; Stanley I Rapoport; Steven J Soldin; Alan T Remaley; Ameer Y Taha; Matthew Kellom; Jianghong Gu; Maureen Sampson; Christopher E Ramsden
Journal:  Biomed Chromatogr       Date:  2012-10-05       Impact factor: 1.902

3.  Organochlorine Pesticides in Honey and Pollen Samples from Managed Colonies of the Honey Bee Apis mellifera Linnaeus and the Stingless Bee Scaptotrigona mexicana Guérin from Southern, Mexico.

Authors:  Jovani Ruiz-Toledo; Rémy Vandame; Ricardo Alberto Castro-Chan; Rosa Patricia Penilla-Navarro; Jaime Gómez; Daniel Sánchez
Journal:  Insects       Date:  2018-05-10       Impact factor: 2.769

4.  Direct injection high performance liquid chromatography coupled to data independent acquisition mass spectrometry for the screening of antibiotics in honey.

Authors:  Annie von Eyken; Daniel Furlong; Samareh Arooni; Fred Butterworth; Jean-François Roy; Jerry Zweigenbaum; Stéphane Bayen
Journal:  J Food Drug Anal       Date:  2019-01-29       Impact factor: 6.157

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.