Literature DB >> 17768220

Treatment of unstable distal radial fractures with the volar locking plating system. Surgical technique.

Kevin C Chung1, Elizabeth A Petruska.   

Abstract

BACKGROUND: The best treatment for an inadequately reduced fracture of the distal part of the radius is not well established. We collected prospective outcomes data for patients undergoing open reduction and internal fixation of an inadequately reduced distal radial fracture with use of the volar locking plating system.
METHODS: Over a two-year period, 161 patients underwent open reduction and internal fixation of an inadequately reduced distal radial fracture with use of the volar locking plating system. Patients were enrolled in the present study three months after the fracture on the basis of strict entry criteria and were evaluated three, six, and twelve months after surgery. Outcome measures included radiographic parameters, grip strength, lateral pinch strength, the Jebsen-Taylor test, wrist range of motion, and the Michigan Hand Outcomes Questionnaire.
RESULTS: Eighty-seven patients with a distal radial fracture were enrolled. The mean age at the time of enrollment was 48.9 years. Forty percent (thirty-five) of the eighty-seven fractures were classified as AO type A, 9% (eight) were classified as type B, and 51% (forty-four) were classified as type C. Radiographic assessment showed that the plating system maintained anatomic reduction at the follow-up periods. At the time of the twelve-month follow-up, the mean grip strength on the injured side was worse than that on the contralateral side (18 compared with 21 kg; p < 0.01), the mean pinch strength on the injured side was not significantly different from that on the contralateral side (8.7 compared with 8.9 kg; p = 0.27), and the mean flexion of the wrist on the injured side was 86% of that on the contralateral side. All Michigan Hand Outcomes Questionnaire domains approached normal scores at six months, with small continued improvement to one year.
CONCLUSIONS: The volar locking plating system appears to provide effective fixation when used for the treatment of initially inadequately reduced distal radial fractures.

Entities:  

Year:  2007        PMID: 17768220     DOI: 10.2106/JBJS.G.00283

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  11 in total

1.  The importance of pronator quadratus repair in the treatment of distal radius fractures with volar plating.

Authors:  Zahab S Ahsan; Jeffrey Yao
Journal:  Hand (N Y)       Date:  2012-09

2.  The pronator quadratus muscle after plating of distal radius fractures: is the muscle still working?

Authors:  Mehmet Armangil; Uğur Bezirgan; Kerem Başarır; Galip Bilen; Mehmet Demirtaş; Sırrı Sinan Bilgin
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-23

3.  Ulnar Styloid Fracture Accompanying Distal Radius Fracture Does Not Affect Hand Function, but What About Hand Dexterity?

Authors:  Hande Usta; Umut Eraslan; Merve Sarıipek; Ali Kitis
Journal:  J Hand Microsurg       Date:  2021-01-07

4.  Volar plate fixation of intra-articular distal radius fractures: a retrospective study.

Authors:  Margaret W M Fok; Melissa A Klausmeyer; Diego L Fernandez; Jorge L Orbay; Alex Lluch Bergada
Journal:  J Wrist Surg       Date:  2013-08

5.  Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique.

Authors:  Matthias Jacobi; Peter Wahl; Georges Kohut
Journal:  J Orthop Surg Res       Date:  2010-08-11       Impact factor: 2.359

6.  The effect of ulnar styloid fractures on patient-rated outcomes after volar locking plating of distal radius fractures.

Authors:  Douglas M Sammer; Hriday M Shah; Melissa J Shauver; Kevin C Chung
Journal:  J Hand Surg Am       Date:  2009-11       Impact factor: 2.230

7.  The Unstable Distal Radius Fracture-How Do We Define It? A Systematic Review.

Authors:  Monique M J Walenkamp; Lara M Vos; Simon D Strackee; J Carel Goslings; Niels W L Schep
Journal:  J Wrist Surg       Date:  2015-11

8.  A comparative study of fragment-specific versus volar plate fixation of distal radius fractures.

Authors:  Douglas M Sammer; Douglas S Fuller; Hyungjin Myra Kim; Kevin C Chung
Journal:  Plast Reconstr Surg       Date:  2008-11       Impact factor: 4.730

9.  A multicenter clinical trial in rheumatoid arthritis comparing silicone metacarpophalangeal joint arthroplasty with medical treatment.

Authors:  Kevin C Chung; Patricia B Burns; E F Shaw Wilgis; Frank D Burke; Marian Regan; H Myra Kim; David A Fox
Journal:  J Hand Surg Am       Date:  2009 May-Jun       Impact factor: 2.230

10.  Economic Analysis of the Cost of Implants Used for Treatment of Distal Radius Fractures.

Authors:  Suneel B Bhat; Frederic E Liss; Pedro K Beredjiklian
Journal:  Arch Bone Jt Surg       Date:  2018-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.