A nomogram for measurement of mitral valve area by proximal isovelocity surface area method.

Mehmet Uzun1, Oben Baysan, Celal Genc, Mehmet Yokusoglu, Hayrettin Karaeren, Ersoy Isik.   

Abstract

INTRODUCTION: Although its accuracy has been documented in many studies, the proximal isovelocity surface area (PISA) method is not used widely for mitral valve area (MVA) measurement. In this study, we prepared a new nomogram and tested its use in MVA assessment.
MATERIAL AND METHODS: The study included 23 patients (age: 27 +/- 5 years) with mitral stenosis, of whom 7 were in atrial fibrillation. The MVA was measured by four methods: planimetry (PL) (reference method), pressure-half time (PHT), conventional PISA (CP), and nomogram (Nomo) methods. The nomogram included two unknowns: (1) r; the radius of the first PISA section; (2) a; the length of the border opposite to the PISA angle in the triangle with both adjacent borders of 1 cm. The nomogram was also tested for its popularity potential by eight echocardiographers, none of whom were included in the author list.
RESULTS: Mean MVA(PL) was 1.85 +/- 0.53 cm(2) (range: 0.72-2.99), mean MVA(PHT) was 1.72 +/- 0.56 cm(2) (range: 0.91-3.30), mean MVA(CP) was 1.69 +/- 0.45 cm(2) (range: 0.97-2.54), and MVA(Nomo) was 1.70 +/- 0.44 cm(2) (0.96-2.49). The nomogram correlated with planimetry (r = 0.87; P < 0.001), pressure half-time (r = 0.71; P < 0.001) and conventional PISA (r = 0.99; P = 0.000) methods. The nomogram method also correlated with planimetry in patients with atrial fibrillation (r = 0.81; P = 0.026). The echocardiographers found that the nomogram is superior to the planimetry and conventional PISA methods but inferior to the pressure half-time method in terms of simplicity.
CONCLUSION: The new nomogram is potentially helpful in measurement of MVA. It may be used as an additional method in assessing severity of mitral stenosis.

Entities:  

Mesh:

Year:  2007        PMID: 17767526     DOI: 10.1111/j.1540-8175.2007.00488.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

1.  Simplifying proximal isovelocity surface area as an assessment method of mitral valve area in patients with rheumatic mitral stenosis by fixing aliasing velocity and mitral valve angle.

Authors:  Alaa Mabrouk Salem Omar; Mohammed Ahmed Abdel-Rahman; Hidekazu Tanaka; Osama Rifaie
Journal:  J Saudi Heart Assoc       Date:  2012-12-04

2.  Radius of proximal isovelocity surface area in the assessment of rheumatic mitral stenosis: Connecting flow to anatomy and hemodynamics.

Authors:  Alaa Mabrouk Salem Omar; Mohamed Ahmed Abdel-Rahman; Hala Raslan; Osama Rifaie
Journal:  J Saudi Heart Assoc       Date:  2015-03-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.