Literature DB >> 17767268

Measuring ocular aberrations in the peripheral visual field using Hartmann-Shack aberrometry.

David A Atchison1, Dion H Scott, W Neil Charman.   

Abstract

We have used the Hartmann-Shack technique previously to measure ocular aberrations along the horizontal meridian of the visual field. This requires considerable modifications from the technique for measuring the aberrations corresponding to the fovea. We now further develop the technique so that it can be used for any meridian of the visual field. Allowance is made for any auxiliary optics placed in front of the eye to compensate for the limited range of the Hartmann-Shack technique and for the case where aberrations are estimated at a wavelength other than the measuring wavelength. Zernike wave aberrations are converted to peripheral refractions. Examples are presented showing the developments, and we discuss change in wave aberrations when converting from a circular to an elliptical pupil.

Year:  2007        PMID: 17767268     DOI: 10.1364/josaa.24.002963

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  7 in total

1.  Comparing the relative peripheral refraction effect of single vision and multifocal contact lenses measured using an autorefractor and an aberrometer: A pilot study.

Authors:  Ravi C Bakaraju; Cathleen Fedtke; Klaus Ehrmann; Arthur Ho
Journal:  J Optom       Date:  2015-02-07

2.  Hyperspectral Shack-Hartmann test.

Authors:  Gabriel C Birch; Michael R Descour; Tomasz S Tkaczyk
Journal:  Appl Opt       Date:  2010-10-01       Impact factor: 1.980

3.  Neural adaptation to peripheral blur in myopes and emmetropes.

Authors:  Atanu Ghosh; Len Zheleznyak; Antoine Barbot; HaeWon Jung; Geunyoung Yoon
Journal:  Vision Res       Date:  2016-12-18       Impact factor: 1.886

4.  Comparison of wavefront aberrations in the object and image spaces using wide-field individual eye models.

Authors:  Yongji Liu; Xiaolan Li; Lin Zhang; Xianglong Yi; Yuwei Xing; Kunqi Li; Yan Wang
Journal:  Biomed Opt Express       Date:  2022-08-25       Impact factor: 3.562

5.  Design and validation of a scanning Shack Hartmann aberrometer for measurements of the eye over a wide field of view.

Authors:  Xin Wei; Larry Thibos
Journal:  Opt Express       Date:  2010-01-18       Impact factor: 3.894

6.  Peripheral refraction and higher-order aberrations with cycloplegia and fogging lenses using the BHVI-EyeMapper.

Authors:  Ravi Chandra Bakaraju; Cathleen Fedtke; Klaus Ehrmann; Darrin Falk; Varghese Thomas; Brien Anthony Holden
Journal:  J Optom       Date:  2015-07-17

7.  The BHVI-EyeMapper: peripheral refraction and aberration profiles.

Authors:  Cathleen Fedtke; Klaus Ehrmann; Darrin Falk; Ravi C Bakaraju; Brien A Holden
Journal:  Optom Vis Sci       Date:  2014-10       Impact factor: 1.973

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.