Literature DB >> 17765074

Determination of nateglinide in human plasma by high-performance liquid chromatography with pre-column derivatization using a coumarin-type fluorescent reagent.

Danai Malli1, Evagelos Gikas, Andreas Vavagiannis, Michael Kazanis, Konstantinos Daniilides, Dimitra Gennimata, Irene Panderi.   

Abstract

A sensitive and selective high-performance liquid chromatographic method has been developed and validated for the determination of nateglinide in human plasma. Nateglinide and the internal standard, undecylenic acid, were extracted from plasma by liquid-liquid extraction using a mixture of ethyl acetate-diethyl ether, 50:50 (v/v). Pre-column derivatization reaction was performed using a coumarin-type fluorescent reagent, N-(7-methoxy-4-methyl-2-oxo-2H-6-chromenyl)-2-bromoacetamide. The derivatization proceeded in acetone in the presence of potassium carbonate and catalyzed by 18-crown-6 ether. The fluorescent derivatives were separated under isocratic conditions on a Hypersil BDS-C8 analytical column (250.0 mm x 2.1 mm i.d., particle size 5 microm) with a mobile phase that consisted of 65% acetonitrile in water and pumped at a flow rate of 0.50 mL min(-1). The excitation and emission wavelengths were set at 345 and 435 nm, respectively. The assay was linear over a concentration range of 0.05-16.00 microg mL(-1) for nateglinide with a limit of quantitation of 0.05 microg mL(-1). Quality control samples (0.05, 4.50 and 16.00 microg mL(-1)) in five replicates from five different runs of analysis demonstrated intra-assay precision (%coefficient of variation <6.8%), inter-assay precision (%coefficient of variation <1.6%) and an overall accuracy (%relative error) less than -3.4%. The method can be used to quantify nateglinide in human plasma covering a variety of pharmacokinetic or bioequivalence studies.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17765074     DOI: 10.1016/j.aca.2007.08.004

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Stability-indicating HPTLC method for simultaneous determination of nateglinide and metformin hydrochloride in pharmaceutical dosage form.

Authors:  Asha Byju Thomas; Shrikrushna Digambar Patil; Rabindra Kumar Nanda; Lata Prasad Kothapalli; Shital Shridhar Bhosle; Avinash Devidas Deshpande
Journal:  Saudi Pharm J       Date:  2011-07-05       Impact factor: 4.330

2.  Separation and quantification of eight antidiabetic drugs on a high-performance liquid chromatography: its application to human plasma assay.

Authors:  Karunanidhi S Lakshmi; Tirumala Rajesh
Journal:  ISRN Pharm       Date:  2011-07-12

3.  Simultaneous Quantification of Antidiabetic Agents in Human Plasma by a UPLC-QToF-MS Method.

Authors:  Mariana Millan Fachi; Letícia Bonancio Cerqueira; Letícia Paula Leonart; Thais Martins Guimarães de Francisco; Roberto Pontarolo
Journal:  PLoS One       Date:  2016-12-08       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.