Literature DB >> 17764833

Determination of trace lead in water samples by continuous flow microextraction combined with graphite furnace atomic absorption spectrometry.

Jing Cao1, Pei Liang, Rui Liu.   

Abstract

A new method of continuous flow microextraction (CFME) combined with graphite furnace atomic absorption spectrometry (GFAAS) was proposed for the determination of trace lead in water samples. A drop of 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP) dissolved in benzene is injected into a glass chamber by a microsyringe and held at the outlet tip of a PTFE connecting tube, the sample solution flows right through the tube and the glass chamber, the solvent drop interacts continuously with the sample solution, and the analyte was extracted into the drop and concentrated. After extracting for a period of time, the drop was retracted into the microsyringe and directly injected into graphite furnace for determination of Pb. Several factors affecting the extraction efficiency, such as solution pH, sample flow rate, drop volume and extraction time, were optimized. Under the optimized conditions, a concentration factor of 45 was achieved, and the detection limits for Pb were 12 pg mL(-1). The relative standard deviation for six replicate analyses of 10 ng mL(-1) Pb was 6.8%. The proposed method was applied to determine of trace Pb in water samples with satisfactory results.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17764833     DOI: 10.1016/j.jhazmat.2007.07.064

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  3 in total

Review 1.  Cloud point extraction coupled with back extraction: a green methodology in analytical chemistry.

Authors:  Shivpoojan Kori
Journal:  Forensic Sci Res       Date:  2019-09-18

2.  A Method to Determination of Lead Ions in Aqueous Samples: Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction Method Based on Solidification of Floating Organic Drop and Back-Extraction Followed by FAAS.

Authors:  Çiğdem Arpa; Itır Aridaşir
Journal:  J Anal Methods Chem       Date:  2018-08-01       Impact factor: 2.193

3.  Pseudo-stir bar hollow fiber solid/liquid phase microextraction combined with anodic stripping voltammetry for determination of lead and cadmium in water samples.

Authors:  Zarrin Es'haghi; Hasan Ali Hoseini; Saeed Mohammadi-Nokhandani; Javad Ebrahimi
Journal:  J Adv Res       Date:  2013-11-20       Impact factor: 10.479

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.