Literature DB >> 17763346

Optimized balanced steady-state free precession magnetization transfer imaging.

O Bieri1, K Scheffler.   

Abstract

Balanced steady-state free precession (bSSFP) suffers from a considerable signal loss in tissues. This apparent signal reduction originates from magnetization transfer (MT) and may be reduced by an increase in repetition time or by a reduction in flip angle. In this work, MT effects in bSSFP are modulated by a modification of the bSSFP sequence scheme. Strong signal attenuations are achieved with short radio frequency (RF) pulses in combination with short repetition times, whereas near full, i.e., MT-free, bSSFP signal is obtained by a considerable prolongation of the RF pulse duration. Similar to standard methods, the MT ratio (MTR) in bSSFP depends on several sequence parameters. Optimized bSSFP protocol settings are derived that can be applied to various tissues yielding maximal sensitivity to MT while minimizing contribution from other impurities, such as off-resonances. Evaluation of MT in human brain using such optimized bSSFP protocols shows high correlation with MTR values from commonly used gradient echo (GRE) sequences. In summary, a novel method to generate MTR maps using bSSFP image acquisitions is presented and factors that optimize and influence this contrast are discussed. Copyright (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17763346     DOI: 10.1002/mrm.21326

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Limitations of rapid myelin water quantification using 3D bSSFP.

Authors:  C Lenz; M Klarhöfer; K Scheffler
Journal:  MAGMA       Date:  2010-04-28       Impact factor: 2.310

2.  MTR variations in normal adult brain structures using balanced steady-state free precession.

Authors:  Meritxell Garcia; Monika Gloor; Oliver Bieri; Stephan G Wetzel; Ernst-Wilhelm Radue; Klaus Scheffler
Journal:  Neuroradiology       Date:  2010-05-18       Impact factor: 2.804

3.  Biochemical (T2, T2* and magnetisation transfer ratio) MRI of knee cartilage: feasibility at ultra-high field (7T) compared with high field (3T) strength.

Authors:  Goetz H Welsch; Sebastian Apprich; Stefan Zbyn; Tallal C Mamisch; Vladimir Mlynarik; Klaus Scheffler; Oliver Bieri; Siegfried Trattnig
Journal:  Eur Radiol       Date:  2010-12-12       Impact factor: 5.315

Review 4.  Nonconventional MRI and microstructural cerebral changes in multiple sclerosis.

Authors:  Christian Enzinger; Frederik Barkhof; Olga Ciccarelli; Massimo Filippi; Ludwig Kappos; Maria A Rocca; Stefan Ropele; Àlex Rovira; Torben Schneider; Nicola de Stefano; Hugo Vrenken; Claudia Wheeler-Kingshott; Jens Wuerfel; Franz Fazekas
Journal:  Nat Rev Neurol       Date:  2015-11-03       Impact factor: 42.937

5.  MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout.

Authors:  Yun Jiang; Dan Ma; Nicole Seiberlich; Vikas Gulani; Mark A Griswold
Journal:  Magn Reson Med       Date:  2014-12-09       Impact factor: 4.668

6.  Magnetization transfer ratio in lesions rather than normal-appearing brain relates to disability in patients with multiple sclerosis.

Authors:  Michael Amann; Athina Papadopoulou; Michaela Andelova; Stefano Magon; Nicole Mueller-Lenke; Yvonne Naegelin; Christoph Stippich; Ernst Wilhelm Radue; Oliver Bieri; Ludwig Kappos; Till Sprenger
Journal:  J Neurol       Date:  2015-06-05       Impact factor: 4.849

7.  Analysis of mcDESPOT- and CPMG-derived parameter estimates for two-component nonexchanging systems.

Authors:  Mustapha Bouhrara; David A Reiter; Hasan Celik; Kenneth W Fishbein; Richard Kijowski; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-07-03       Impact factor: 4.668

8.  Balanced Steady-State Free Precession (bSSFP) from an effective field perspective: Application to the detection of chemical exchange (bSSFPX).

Authors:  Shu Zhang; Zheng Liu; Aaron Grant; Jochen Keupp; Robert E Lenkinski; Elena Vinogradov
Journal:  J Magn Reson       Date:  2016-12-08       Impact factor: 2.229

9.  Prediction of myocardial signal during CINE balanced SSFP imaging.

Authors:  Kyunghyun Sung; Hsu-Lei Lee; Houchun H Hu; Krishna S Nayak
Journal:  MAGMA       Date:  2010-03-13       Impact factor: 2.310

10.  Mapping primary gyrogenesis during fetal development in primate brains: high-resolution in utero structural MRI of fetal brain development in pregnant baboons.

Authors:  Peter Kochunov; Carlos Castro; Duff Davis; Donald Dudley; Jordan Brewer; Yi Zhang; Christopher D Kroenke; David Purdy; Peter T Fox; Calvin Simerly; Gerald Schatten
Journal:  Front Neurosci       Date:  2010-05-10       Impact factor: 4.677

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.