Novel Compliance Index derived from digital volume pulse associated with risk factors and exercise capacity in patients undergoing treadmill exercise tests.

Ju-Yi Chen1, Wei-Chuan Tsai, Ming-Sheng Wu, Chih-Hsin Hsu, Chih-Chan Lin, Hsien-Tsai Wu, Li-Jen Lin, Jyh-Hong Chen.   

Abstract

OBJECTIVE: Although large-artery stiffness is a well-known independent factor for cardiovascular risk, the importance of small-artery stiffness is not well elucidated. We have developed a novel Compliance Index as a marker of small-artery stiffness. This study aimed to determine the clinical significance of this index by evaluating 140 patients without left ventricular dysfunction referred for treadmill exercise tests.
METHODS: Immediately after a 10-min rest period before the test, the pulse wave velocity and Compliance Index were measured. The patients were then given a symptom-limited treadmill test using Bruce's protocol. Our dual-channel photoplethysmography system automatically measured the area under the curve of each digital volume pulse, which represented the volume change in the finger with each heart beat. The Compliance Index was calculated by dividing the area under the curve of finger digital volume pulse by pulse pressure.
RESULTS: The Compliance Index was significantly correlated with pulse wave velocity (r=-0.254, P=0.002), systolic blood pressure (r=-0.606, P<0.001), and diastolic blood pressure (r=-0.323, P<0.001). It was lower in males (3.3+/-1.4 versus 4.8+/-2.4 units, P<0.001), in hypertensive patients (3.2+/-1.5 versus 4.4+/-2.2 units, P<0.001), and in smokers (3.0+/-1.5 versus 4.1+/-2.1 units, P=0.006).
CONCLUSIONS: The Compliance Index was lower in patients with risk factors and was associated with poor exercise capacity. This index may be clinically useful for evaluating arterial stiffness.

Entities:  

Mesh:

Year:  2007        PMID: 17762654     DOI: 10.1097/HJH.0b013e328244e3ac

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  3 in total

1.  Compliance Index, a Marker of Peripheral Arterial Stiffness, may Predict Renal Function Decline in Patients with Chronic Kidney Disease.

Authors:  Te-Hui Kuo; Deng-Chi Yang; Wei-Hung Lin; Chin-Chung Tseng; Ju-Yi Chen; Chin-Shan Ho; Meng-Fu Cheng; Wei-Chuan Tsai; Ming-Cheng Wang
Journal:  Int J Med Sci       Date:  2015-06-12       Impact factor: 3.738

2.  The photoplethysmographic amplitude to pulse pressure ratio can track sudden changes in vascular compliance and resistance during liver graft reperfusion: A beat-to-beat analysis.

Authors:  Wook-Jong Kim; Jung-Won Kim; Young-Jin Moon; Sung-Hoon Kim; Gyu-Sam Hwang; Won-Jung Shin
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

3.  The answer at our fingertips: Volume status in cirrhosis determined by machine learning and pulse oximeter waveform.

Authors:  Nikhilesh R Mazumder; Avidor Kazen; Andrew Carek; Mozziyar Etemadi; Josh Levitsky
Journal:  Physiol Rep       Date:  2022-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.