An experimental MOSFET approach to characterize (192)Ir HDR source anisotropy.

W C Toye1, K R Das, S P Todd, M B Kenny, R D Franich, P N Johnston.   

Abstract

The dose anisotropy around a (192)Ir HDR source in a water phantom has been measured using MOSFETs as relative dosimeters. In addition, modeling using the EGSnrc code has been performed to provide a complete dose distribution consistent with the MOSFET measurements. Doses around the Nucletron 'classic' (192)Ir HDR source were measured for a range of radial distances from 5 to 30 mm within a 40 x 30 x 30 cm(3) water phantom, using a TN-RD-50 MOSFET dosimetry system with an active area of 0.2 mm by 0.2 mm. For each successive measurement a linear stepper capable of movement in intervals of 0.0125 mm re-positioned the MOSFET at the required radial distance, while a rotational stepper enabled angular displacement of the source at intervals of 0.9 degrees . The source-dosimeter arrangement within the water phantom was modeled using the standardized cylindrical geometry of the DOSRZnrc user code. In general, the measured relative anisotropy at each radial distance from 5 mm to 30 mm is in good agreement with the EGSnrc simulations, benchmark Monte Carlo simulation and TLD measurements where they exist. The experimental approach employing a MOSFET detection system of small size, high spatial resolution and fast read out capability allowed a practical approach to the determination of dose anisotropy around a HDR source.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17762089     DOI: 10.1088/0031-9155/52/17/015

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Comparative dosimetry of GammaMed Plus high-dose rate Ir brachytherapy source.

Authors:  N P Patel; B Majumdar; V Vijayan
Journal:  J Med Phys       Date:  2010-07

2.  Review of fast monte carlo codes for dose calculation in radiation therapy treatment planning.

Authors:  Keyvan Jabbari
Journal:  J Med Signals Sens       Date:  2011-01

3.  Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

Authors:  Antony Palmer; David Bradley; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-06-30

4.  Quality assurance during interstitial brachytherapy: in vivo dosimetry using MOSFET dosimeters.

Authors:  Corinna Melchert; Tamer Soror; György Kovács
Journal:  J Contemp Brachytherapy       Date:  2018-06-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.